Telusuri Gambar Maps YouTube Berita Gmail Drive Kalender Lainnya »
Login
Buku Buku
" As soon as the stronger solution is taken from the vessel containing the unfiltered neutralized stock solution, additional crystals and water must be added to the stock solution. An excess of cupric oxide shall always be kept in the unfiltered stock solution. "
Convention - Halaman 579
oleh National Electric Light Association. Convention - 1913
Tampilan utuh - Tentang buku ini

Proceedings of the American Electric Railway Association

American Electric Railway Association - 1911
[ Maaf, isi halaman ini tidak dapat ditampilkan ]
Tampilan cuplikan - Tentang buku ini

Proceedings of the American Electric Railway Association

American Electric Railway Association - 1919
[ Maaf, isi halaman ini tidak dapat ditampilkan ]
Tampilan cuplikan - Tentang buku ini

Proceedings of the American Electric Railway Association

American Electric Railway Association - 1920
...crystals and water. An excess of cupric oxide shall always be kept in the unfiltered stock solution. Quantity of Solution: Wire samples shall be tested in a glass jar or not less than two inches inside diameter filled to a depth of not less than four inches with the...
Tampilan utuh - Tentang buku ini

Transmission Line Construction, Methods and Costs

Ruben Alvin Lundquist - 1912 - 295 halaman
...solution of a higher specific gravity shall be added to make the specific gravity 1.186 at 65 F. As soon as the stronger solution is taken from the...shall be tested in a glass jar of at least two (2) in. inside diameter. The jar without the wire samples shall be filled with standard solution to a depth...
Tampilan utuh - Tentang buku ini

Transmission Line Construction, Methods and Costs

Ruben Alvin Lundquist - 1912 - 295 halaman
...solution of a higher specific gravity shall be added to make the specific gravity 1.186 at 65 F. As soon as the stronger solution is taken from the...Solution. — Wire samples shall be tested in a glass j ar of at least two (2) in. inside diameter. The j ar without the wire samples shall be filled with...
Tampilan utuh - Tentang buku ini

Bulletin - American Railway Engineering Association, Volume 16

American Railway Engineering Association - 1914
...higher specific gravity shall be added to make the specific gravity 1.186 at 65 degrees Fahrenheit. As soon as the stronger solution is taken from the...shall always be kept in the unfiltered stock solution. Quantity of Solution. (d) Wire samples shall be tested in a glass jar of at least two (2) inches inside...
Tampilan utuh - Tentang buku ini

Proceedings of the American Electric Railway Association

American Electric Railway Association - 1914
[ Maaf, isi halaman ini tidak dapat ditampilkan ]
Tampilan cuplikan - Tentang buku ini

Commission Leaflets: Recent Commission Orders, Rulings and ..., Masalah 35-41

American Telephone and Telegraph Company. Bureau of Commission Research. Legal Dept - 1915
...higher specific gravity shall be added to make the specific gravity 1.186 at 65 degrees Fahrenheit. As soon as the stronger solution is taken from the...samples shall be tested in a glass jar of at least two inches inside diameter. The jar without the wire samples shall be filled with standard solution to...
Tampilan utuh - Tentang buku ini

Galvanizing and Tinning: A Practical Treatise on the Coating of Metal with ...

William Thomas Flanders, John Calder, R. D. Foster - 1916 - 350 halaman
...solution is high in specific gravity, clean water shall be added to reduce the specific gravity to 1.186 at 65 deg. Fahr. In case the filtered solution...shall always be kept in the unfiltered stock solution. Quantity of Solution Wire samples shall be tested in a glass jar of at least two inches (2 in.) inside...
Tampilan utuh - Tentang buku ini




  1. Koleksiku
  2. Bantuan
  3. Penelusuran Buku Lanjutan
  4. Download ePub
  5. Download PDF