As soon as the stronger solution is taken from the vessel containing the unfiltered neutralized stock solution, additional crystals and water must be added to the stock solution. An excess of cupric oxide shall always be kept in the unfiltered stock solution. Convention - Halaman 579oleh National Electric Light Association. Convention - 1913Tampilan utuh - Tentang buku ini
| Robert Duncan Coombs - 1916 - 304 halaman
...filtered solution of a higher specific gravity shall be added to make the specific gravity 1.186 at 65°F. As soon as the stronger solution is taken from the...shall be tested in a glass jar of at least two (2) in. inside diameter. The jar without the wire samples shall- be filled with standard solution to a... | |
| Robert Duncan Coombs - 1916 - 288 halaman
...filtered solution of a higher specific gravity shall be added to make the specific gravity 1.186 at 65F. As soon as the stronger solution is taken from the...shall always be kept in the unfiltered stock solution. D.QUANTITY OF SOLUTION.@Wire samples shall be tested in a glass jar of at least two (2) in. inside... | |
| Lamar Lyndon - 1916 - 376 halaman
...filtered solution of a higher specific gravity shall be added to make the specific gravity 1.186 at 65°F. As soon as the stronger solution is taken from the vessel containing the filtered neutralized stock solution, additional crystals and water must be added to the stock solution.... | |
| American Railway Association. Telegraph and Telephone Section - 1919 - 428 halaman
...specific gravity one and one hundred eighty-six thousandths (1.186) at sixty-five (65) degrees F. (c) As soon as the stronger solution is taken from the...unfiltered neutralized stock solution, additional Iron and AMERICAN RAILROAD ASSOCIATION Steel crystals and water must be added to the stock solution.... | |
| Roger Castle Griffin - 1921 - 696 halaman
...sp. gr., a filtered solution of a higher sp. gr. shall be added to make the sp. gr. 1.186 at 65° F. As soon as the stronger solution is taken from the...must be added to the stock solution. An excess of CuO shall always be kept in the unfiltered stock solution. Quantity of Solution. — Wire samples shall... | |
| American Railway Engineering Association - 1921 - 1442 halaman
...shall be replenished after each removal T)y the addition of more copper sulphate crystals and water. An excess of cupric oxide shall always be kept in the unfiltered stock solution. Quantity of Solution — Wire samples shall be tested in a glass jar of not less than two inches inside... | |
| Harold Pender, William Arthur Del Mar - 1922 - 2306 halaman
...solution of a higher specific gravity shall be added to make the specific gravity 1.186 at 65° F. As soon as the stronger solution is taken from the...excess of cupric oxide shall always be kept in the unaltered stock solution. (d) Quantity of Solution. — Wire samples shall be tested in a glass jar... | |
| Roger Castle Griffin - 1927 - 968 halaman
...65° F. In case the filtered solution is low in sp. gr., add a filtered solution of a higher sp. gr. As soon as the stronger solution is taken from the...must be added to the stock solution. An excess of CuO must always be kept in the unfiltered stock solution. Quantity of Solution. — Test wire samples... | |
| Roger Castle Griffin - 1927 - 970 halaman
...65° F. In case the filtered solution is low in sp. gr., add a filtered solution of a higher sp. gr. As soon as the stronger solution is taken from the vessel containing the unaltered neutralized stock solution, additional crystals and water must be added to the stock solution.... | |
| United States. Department of Agriculture - 1924 - 1056 halaman
...solution of a higher specific gravity shall be added to make the specific gravity 1.186 at 65° F. 7. As soon as the stronger solution is taken from the...must be added to the stock solution. An excess of cuprlc oxide shall always be kept in the unflltered stock solution. 8. (rf) Quantity of solution. —... | |
| |