" Conductors: The conductors shall be of copper, aluminum, or other non-corrodible material, except that in exceptionally long spans, where the required mechanical strength cannot be obtained with the above materials, galvanized or copper-covered steel... "
Proceedings of the American Electric Railway Engineering Association ... - Halaman 119
oleh American Electric Railway Engineering Association. Convention, American Electric Railway Association - 1911
Tampilan utuh - Tentang buku ini

Convention, Volume 4

National Electric Light Association. Convention - 1913 - 842 halaman
...Spark-Gap Method. 43 Test voltages below 35,000 volts shall be determined ttransformer ratio. MATERIAL 44 Conductors: The conductors shall be of copper, aluminum, or other non-corrodible material, except that in unusually long spans, where the required mechanical strength cannot be obtained with the above materials,...
Tampilan utuh - Tentang buku ini

Proceedings of the American Electric Railway Association, Volume 31

American Electric Railway Association - 1912 - 1008 halaman
[ Maaf, isi halaman ini tidak dapat ditampilkan ]
Tampilan cuplikan - Tentang buku ini

Proceedings of the American Electric Railway Association

American Electric Railway Association - 1913 - 722 halaman
[ Maaf, isi halaman ini tidak dapat ditampilkan ]
Tampilan cuplikan - Tentang buku ini

Annual Report, Volume 4

Arizona Corporation Commission - 1913 - 948 halaman
...exceeding 60,000.... 120,000 Exceeding 60,000 twice the line voltage 39. Test voltages above 35,000 volts shall be determined by the AIEE Standard Spark-Gap...conductors shall be of copper, aluminum, or other uon-corrodible material, except that in exceptionally lon^ spans, where the required mechanical strength...
Tampilan utuh - Tentang buku ini

Annual Report, Volume 4

Arizona Corporation Commission - 1915 - 792 halaman
[ Maaf, isi halaman ini tidak dapat ditampilkan ]
Tampilan cuplikan - Tentang buku ini

Decisions of the Railroad Commission of the State of California, Volume 10

Railroad Commission of the State of California - 1916 - 782 halaman
...bridges shall be used except where special permission is granted by the Commission. Materials. 12. (a) Conductors. The conductors shall be of copper, aluminum, or other non-corrodible material except where the required mechanical strength can not be obtained with the above materials ; if properly protected...
Tampilan utuh - Tentang buku ini

Bulletin - American Railway Engineering Association, Volume 16

American Railway Engineering Association - 1914 - 1224 halaman
...42. Test voltages above 35,000 volts shall be determined by the AI EE Standard Spark-Gap Method. 43. Test voltages below 35,000 volts shall be determined by transformer ratio. MATERIAL. Conductors. 44. The conductors shall be of copper, aluminum, or other non-corrodible material, except...
Tampilan utuh - Tentang buku ini

Electric Railway Handbook: A Reference Book of Practice Data, Formulas and ...

Albert Sutton Richey, William Charles Greenough - 1915 - 850 halaman
...Method. 43. Test voltages below 35,000 volts shall be determined by transformer ratio. 44. Material. Conductors. The conductors shall be of copper, aluminum,...galvanized or copper-covered steel strand may be used. 45. For voltages not exceeding 750 volts, solid or stranded conductors may be used up to and including...
Tampilan utuh - Tentang buku ini

Electric Railway Handbook: A Reference Book of Practice Data, Formulas and ...

Albert Sutton Richey, William Charles Greenough - 1915 - 852 halaman
...Method. 43. Test voltages below 35,000 volts shall be determined by transformer ratio. 44. Material. Conductors. The conductors shall be of copper, aluminum,...be obtained with the above materials, galvanized or npcr-covered steel strand may be used. OVERHEAD CROSSINGS 651 45. For voltages not exceeding 750 volts,...
Tampilan utuh - Tentang buku ini

Commission Leaflets: Recent Commission Orders, Rulings and ..., Masalah 35-41

American Telephone and Telegraph Company. Bureau of Commission Research. Legal Dept - 1915 - 1612 halaman
...Spark-Gap Method. 29. Test voltages below 35,000 volts shall be determined by transformer ratio. 30. CONDUCTORS: The conductors shall be of copper, aluminum or other non-corrodible material, or of steel covered with such non-corrodible material. 31. Conductors shall be of such mechanical strength...