| Gaetano Lanza - 1905 - 980 halaman
...inches wide up to ico inches wide, 5 per cent above or 3 per cent below the theoretical weight. When ico inches wide and over, 10 per cent above or 3 per cent below the theoretical weight. (f) For all plates ordered to gauge there will be permitted an average excess of weight over that corresponding... | |
| Alfred William Farnsworth - 1905 - 338 halaman
...wide up to 100 in. wide, 5 per cent. alx)ve or 3 per cent. below the theoretical weight. When 100 in. wide and over, 10 per cent. above or 3 per cent. below the theoretical weight. (/•) For all plates ordered to gauge there will be permitted an average excess of weight over that... | |
| Robert H. Thurston - 1906 - 808 halaman
...below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent, above or 3 per cent, below the theoretical weight. When 100 inches wide...above or 3 per cent, below the theoretical weight. ********* (g) For all plates ordered to gauge, there will be permitted an average excess of weight... | |
| Cambria Steel Co - 1906 - 506 halaman
...below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent, above or 3 per cent, below the theoretical weight. When 100 inches wide...above or 3 per cent, below the theoretical weight. c.For all plates ordered to gauge there will be permitted an aver age excess of weight over that corresponding... | |
| Albert Wells Buel - 1906 - 96 halaman
...wide up to 100 inches wide, 5 per cent. above or 3 per cent. below the theoretical weight; when loo inches wide and over, 10 per cent. above or 3 per cent. below the theoretical weight. TABLE OF ALLOWANCES FOR OVERWEIGHT FOR RECTANGULAR PLATES WHEN ORDERED TO GAUGE. Plates will be considered... | |
| American Railway Engineering and Maintenance-of-Way Association - 1907 - 308 halaman
...Seventy-five inches and up to 100 in. wide, 5 per cent. above or 3 per cent. below. (c) One hundred inches wide and over, 10 per cent. above or 3 per cent. below. 104. Plates will be accepted if they measure not more than o.o1 in. below the ordered thickness. 105.... | |
| Milo Smith Ketchum - 1907 - 430 halaman
...Seventy-five inches and up to 100 inches wide, 5 per cent above or 3 per cent below. (c) One hundred inches wide and over, 10 per cent above or 3 per cent below. PLATES % INCH AND OVER IN THICKNESS. PLATES UNDER J4 INCH IN THICKNESS.* Ordered. Weight. W1dth of... | |
| Cecil Hobart Peabody, Edward Furber Miller - 1908 - 488 halaman
...below the theoretical weight. 75 inches wide up to 100 inches wide, 5 per cent above or 3 per cent below the theoretical weight. When 100 inches wide...above or 3 per cent below the theoretical weight. (g) For all plates ordered to gauge, there will be permitted an average excess of weight over that... | |
| Glasgow Iron Company - 1909 - 120 halaman
...below the theoretical weight, 75 inches wide up to 100 inches wide. 5 per cent, above or 3 per cent, below the theoretical weight, When 100 inches wide...above or 3 per cent, below the theoretical weight, л For all plates ordered to gauge there will be permitted an average excess of weight over that corresponding... | |
| 1909 - 714 halaman
...theoretical weight. Seventyfive inches wide up to 100 inches wide, 5 per cent, above or 3 per cent, below the theoretical weight. When 100 inches wide and over, 10 per cent, or 3 per cent, below the theoretical weight. For all plates ordered to gage there will be permitted... | |
| |