" Wrought Iron. All wrought iron shall be uniform in character, fibrous, tough and ductile. It shall have an ultimate tensile resistance of not less than 48,000- pounds per square inch, an elastic limit of not less than 24,000 pounds per square inch, and... "
Erection and Inspection of Iron and Steel Constructions: Written for the Use ... - Halaman 131
oleh Lupescu Morris Bernfeld - 1913 - 225 halaman
Tampilan utuh - Tentang buku ini

Proceedings of the Board of Trustees of the Sanitary District of Chicago

Chicago Sanitary District. Board of Trustees - 1903 - 620 halaman
...(JCALITY OF MATERIAL. Wrought Iron. 8. All wrought iron used shall have au ultimate tensile strength of not less than 48,000 pounds per square Inch, an elastic limit of at least 26,000 pounds per square inch, and an elongation of at least 20 per cent in eight Inches,...
Tampilan utuh - Tentang buku ini

Engineering Contracts and Specifications: Including a Brief Synopsis of the ...

John Butler Johnson - 1904 - 598 halaman
...specimens broken in a testing machine shall show a tensile strength of not less than 60,000 pound.5 per square inch, and an elongation of 20 per cent. in eight diameters. 101. Finished bolts and nuts of Tobin or Phosphor bronze may be tested in the same manner...
Tampilan utuh - Tentang buku ini

Types and Details of Bridge Construction: Arch spans

Frank Woodward Skinner - 1904 - 316 halaman
...basic open-hearth steel with a tensile strength of 62,000 to 68,000 and an elastic limit of 33,000 pounds per square inch and an elongation of 20 per cent, in 8 inches. The maximum pressure on the top of the masonry of both abutments on each side of the river...
Tampilan utuh - Tentang buku ini

Municipal Ordinances of the City of Troy: Rules and Regulations of the ...

1905 - 468 halaman
...such size and dimensions as the purposes for which the buildings is intended require. Wrought Iron — Wrought iron shall be uniform in character, fibrous,...have an ultimate tensile resistance of not less than forty-eight thousand pounds per square inch, an elastic limit of not less than 'twenty-four thousand...
Tampilan utuh - Tentang buku ini

National Building Code

1905 - 274 halaman
...SECTION 21. Structural Material. yuamy and . WROUGHT IRON. All wrought iron shall be uni•trenstn. form in character, fibrous, tough and ductile. It shall...ultimate tensile resistance of not less than 48,000 Ibs. per square inch, an elastic limit of not less than 24,000 Ibs. per square inch, and an elongation...
Tampilan utuh - Tentang buku ini

Building Ordinance, Adopted March 20, 1905: Amended March 1, 1906 - June 18 ...

Troy (N.Y.). - 1906 - 72 halaman
...such size and dimensions as the purposes for which the buildings is intended require. Wrought Iron — Wrought iron shall be uniform in character, fibrous,...have an ultimate tensile resistance of not less than forty-eight thousand pounds per square inch, an elastic limit of not less than twenty-four thousand...
Tampilan utuh - Tentang buku ini

The Building Law of the City and County of San Francisco for 1906

San Francisco (Calif.) - 1906 - 130 halaman
...piles in so far as applicable. Wrought Iron. Section 36. All wrought iron shall be uniform and fibrous. It shall have an ultimate tensile resistance of not less than 48,000 pounds per square inch, and elastic limit of not less than 24,000 pounds per square inch, and an elongation of 20 per centum...
Tampilan utuh - Tentang buku ini

National Building Code

1907 - 276 halaman
...direct shall be made. SECTION 21. Quality and •trength. Quality and strength. Structural Material. WROUGHT IRON. All wrought iron shall be uniform in...ultimate tensile resistance of not less than 48,000 Ibs. per square inch, an elastic limit of not less than 24,000 Ibs. per square inch, and an elongation...
Tampilan utuh - Tentang buku ini

Proceedings of the American Street and Interurban Railway Association, Volume 2

American Street and Interurban Railway Association - 1907 - 826 halaman
...fibrous, tough and ductile. It shall have strength, an ultimate tensile resistance of not less than 48.000 pounds per square inch, an elastic limit of not less...24,000 pounds per square inch, and an elongation of twenty per cent, in eight inches, when tested in small specimens. Steel. AH structural steel shall...
Tampilan utuh - Tentang buku ini

Code of Ordinances of the City of New York

New York (N.Y.) - 1907 - 462 halaman
...results of tests, such as he may direct shall be made. (Id., sec. 20.) § 21. Structural Material; Wrought Iron. — All wrought iron shall be uniform...fibrous, tough and ductile. It shall have an ultimate tensible resistance of not less than 48,000 pounds per square inch, an elastic limit of not less than...