Convention, Volume 32,Bagian 2 |
Dari dalam buku
Hasil 1-3 dari 99
Halaman 316
... pole to the centre of the upper gain shall be twelve inches . 8. Reverse or Buck - Arm Gains . - Where reverse or buck- arms are to be placed on a pole , the cross - gains shall be cut at right angles to the line gains , and twelve ...
... pole to the centre of the upper gain shall be twelve inches . 8. Reverse or Buck - Arm Gains . - Where reverse or buck- arms are to be placed on a pole , the cross - gains shall be cut at right angles to the line gains , and twelve ...
Halaman 328
... pole shall be double armed , as follows : on the opposite side of the pole , and parallel to the regular gain , a second gain shall be cut . Two fully equipped cross - arms shall then be placed one on each side of the pole . Two blocks ...
... pole shall be double armed , as follows : on the opposite side of the pole , and parallel to the regular gain , a second gain shall be cut . Two fully equipped cross - arms shall then be placed one on each side of the pole . Two blocks ...
Halaman 334
... Poles . - All corner poles , whether the turn is made on one pole or on two poles , should be head and side guyed , as shown in Plate No. 28 . 60. Curved Lines . - On curved lines side guys should be installed in line with the radius of ...
... Poles . - All corner poles , whether the turn is made on one pole or on two poles , should be head and side guyed , as shown in Plate No. 28 . 60. Curved Lines . - On curved lines side guys should be installed in line with the radius of ...
Isi
Conventions of the Association | xiii |
ReportEditor of Question Bor Alex J Campbell | xix |
Report Committee on State and Company Branches | xxxiii |
27 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating-current amount angle Anthracite apparatus arc lamps arrester average boiler bolts braces buckets cable capacity cent central station CHAIRMAN circuits City coal coils committee condenser connection construction consumer copper cost cross-arm Curtis curve customers discussion distribution EDISON COMPANY efficiency Elec ELECTRIC LIGHT ASSOCIATION equipment feet Figure galvanized gas engine guy wire heat horse-power illuminating inches increase installation insulation iron kilowatt-hour kilowatts lightning arresters Lignite line wire load factor located loss low-pressure turbine machine manufacturers meter methods motor motor-generator NATIONAL ELECTRIC LIGHT obtained operating overhead line paper Penn pins pipe plant pole possible pounds power factor practice pressure producer pump Rateau reactance secondary shaft shows space specifications speed standard station load steam steel strain strain insulators supply surface condenser synchronous temperature tests tion transformers tungsten lamp vacuum valve voltage volts wattmeter