Halaman 114
... apparatus . Where current transformers are used in connection with a meter and the line volt- age does not exceed 600 volts and the current capacity of the trans- former does not exceed 150 amperes , the meter shall be tested from the ...
... apparatus . Where current transformers are used in connection with a meter and the line volt- age does not exceed 600 volts and the current capacity of the trans- former does not exceed 150 amperes , the meter shall be tested from the ...
Halaman 127
... apparatus in the supply of service for commercial pur- poses . Touching upon developments in apparatus in a general way , we have recorded some examples of recent construction which were worthy of note from the point of view of size and ...
... apparatus in the supply of service for commercial pur- poses . Touching upon developments in apparatus in a general way , we have recorded some examples of recent construction which were worthy of note from the point of view of size and ...
Halaman 689
... Apparatus co - operate with the Electrical Apparatus Committee in the preparation of anything which it intends to send out . I do this for the reason that the Electrical Apparatus Committee has under consideration at the present time ...
... Apparatus co - operate with the Electrical Apparatus Committee in the preparation of anything which it intends to send out . I do this for the reason that the Electrical Apparatus Committee has under consideration at the present time ...
Edisi yang lain - Lihat semua
Istilah dan frasa umum
3-phase Alternating Current alternating-current ammeter amperes apparatus boiler cable capacity cent Chairman circuit coal coil Committee condenser conductor connected construction cost DEMAND INDICATOR designed device direct current distribution diversity factor duct economizer Edison efficiency Elec Electric Company engine equipment feeder Francis turbine fuel fuses gates governor effort ground hydro-electric inductive industry installation instrument insulators kilowatts lamps Light & Power lightning arresters load machine manholes manufacturers maximum ment method miles motor oil switches operation Overhead Line Pacific panels phase pipe plant polyphase potentiometer Power Company practice present pressure pump railway regulation rheostat rules safety secondary short-circuit shunt single-phase standard station steam street substation supply surface condenser switchboard synchronous condensers temperature tion trans transmission turbine unit Utah voltage voltmeter volts water power water wheel water-power watthour meter wattmeter Westinghouse wire