... pressure drop and it , therefore , becomes necessary to provide means in the form of flywheel effect for taking care of the drop of the pressure to secure proper regulation . This flywheel effect can be secured in the revolving part of ...
... pressure drop and it , therefore , becomes necessary to provide means in the form of flywheel effect for taking care of the drop of the pressure to secure proper regulation . This flywheel effect can be secured in the revolving part of ...
Halaman 502
... pressure of 0.75 in while line A shows a pressure of 0.50 in . If it is desir- able to obtain a total pressure of 0.50 in for the condition on line E with the quantity of air mentioned , it will be necessary to double the displacement ...
... pressure of 0.75 in while line A shows a pressure of 0.50 in . If it is desir- able to obtain a total pressure of 0.50 in for the condition on line E with the quantity of air mentioned , it will be necessary to double the displacement ...
Halaman 569
... pressure often drops as much as 40 or even 60 pounds , but we keep our boiler pressure possibly a little higher than we would if we were not operating for stand - by ; that is to say , we run approximately 200 pounds ( our normal pressure ...
... pressure often drops as much as 40 or even 60 pounds , but we keep our boiler pressure possibly a little higher than we would if we were not operating for stand - by ; that is to say , we run approximately 200 pounds ( our normal pressure ...
Edisi yang lain - Lihat semua
Istilah dan frasa umum
ampere-hour amperes apparatus average boilers cable capacity cent central station Chairman charges circuit coal coil Commission Committee condenser conductors connection considerable construction copper cost curve devices direct-current discussion distribution Edison Illuminating Companies efficiency Elec Electricity Meters Elek energy equipment flow ground heat high-tension hydraulic hydro-electric illumination increased indicated induction installation instruments insulation kilowatt-hour kilowatts lamps limits load luminous arc machines manufacturers maximum Mazda measured member companies ment methods mica miles oil engine operating Overhead Line penstocks pipe power plant practice pressure Public Service reactance record regulation resistance rules secondary short-circuit shunt standard steam street lighting substation supply surface switchboard switches synchronous condensers temperature tion transformers transmission lines turbine units utility vacuum pump Venturi meter voltage volts water power water wheel water-power watt-hour meters Wattmeter wheel wire