Halaman 25
... demand indicator ( G. E. Co. ) III Time - Lagged Maximum Demand Instruments ( a ) Leaving a record of the maximum load only Wright ampere demand indicators Watt demand indicators ( G. E. Co. ) Demand watt - hour meters ( Westinghouse ) ...
... demand indicator ( G. E. Co. ) III Time - Lagged Maximum Demand Instruments ( a ) Leaving a record of the maximum load only Wright ampere demand indicators Watt demand indicators ( G. E. Co. ) Demand watt - hour meters ( Westinghouse ) ...
Halaman 140
... demand indicators . When we realize that the only inex- pensive type of demand indicator now in use is the Wright , which has been practically unchanged for the last sixteen years , and compare its development with that of other kinds ...
... demand indicators . When we realize that the only inex- pensive type of demand indicator now in use is the Wright , which has been practically unchanged for the last sixteen years , and compare its development with that of other kinds ...
Halaman 690
... demand of approximately one kilowatt ; the average local residence has a demand of 0.4 kilowatt . Thus 22 residence customers make the same draft upon the local distributing system in the block that is made by one store customer . The ...
... demand of approximately one kilowatt ; the average local residence has a demand of 0.4 kilowatt . Thus 22 residence customers make the same draft upon the local distributing system in the block that is made by one store customer . The ...
Edisi yang lain - Lihat semua
Istilah dan frasa umum
ampere-hour amperes apparatus average boilers cable capacity cent central station Chairman charges circuit coal coil Commission Committee condenser conductors connection considerable construction copper cost curve devices direct-current discussion distribution Edison Illuminating Companies efficiency Elec Electricity Meters Elek energy equipment flow ground heat high-tension hydraulic hydro-electric illumination increased indicated induction installation instruments insulation kilowatt-hour kilowatts lamps limits load luminous arc machines manufacturers maximum Mazda measured member companies ment methods mica miles oil engine operating Overhead Line penstocks pipe power plant practice pressure Public Service reactance record regulation resistance rules secondary short-circuit shunt standard steam street lighting substation supply surface switchboard switches synchronous condensers temperature tion transformers transmission lines turbine units utility vacuum pump Venturi meter voltage volts water power water wheel water-power watt-hour meters Wattmeter wheel wire