... construction . - a . Class 6 Heavy -Heavy timber construction structures are those structures in construction which the exterior walls are of masonry or reinforced concrete structures . with a fire resistive rating of at least three ...
... construction . - a . Class 6 Heavy -Heavy timber construction structures are those structures in construction which the exterior walls are of masonry or reinforced concrete structures . with a fire resistive rating of at least three ...
Halaman 712
... construction . - Unless designed in accordance with the provisions of sections C26-468.0 through C26-509.0 , concrete floor and roof construction shall consist of a mixture of one part of cement by volume , two parts of sand by volume ...
... construction . - Unless designed in accordance with the provisions of sections C26-468.0 through C26-509.0 , concrete floor and roof construction shall consist of a mixture of one part of cement by volume , two parts of sand by volume ...
Halaman 714
... construction . - Gypsum floor and roof construction may be either of reinforced poured gypsum or precast units and may be either of the suspension type or of the slab and ceiling type with the slabs constructed of such thickness as to ...
... construction . - Gypsum floor and roof construction may be either of reinforced poured gypsum or precast units and may be either of the suspension type or of the slab and ceiling type with the slabs constructed of such thickness as to ...
Isi
Table of Sections With Page References | xxii |
Chapter 928 | xxxvii |
Chapter 929 | 1 |
64 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
amount application approved assessment avenue beams board of estimate borough president building car safety certificate charter city collector column combustible commissioner comply comptroller concrete construction corporation counsel counterweight court designed device distance dollars dumbwaiter duty East One hundred East river elevator enclosure exit factor of safety Fahrenheit fee title fifty filed fire resistive rating fireproof floor fund gypsum height hoistway doors inches incombustible issued landing least license live load load located masonry material maximum means of egress ment metal notice one-half operation owner paid partitions payment pension permit person pounds per square premises proceeding real property reinforcement retirement roof safety sidewalk square inch stairways steel storage street structure SUB-ARTICLE subdivision superintendent tax lien taxicab thence therein thereof thereto tion transfer of tax unlawful vomitories walls width