... track feeder system is one in which the return feeders are electrically in parallel with the tracks . Under such circum- stances the cables may be operating very inefficiently as current conductors and as a means of reducing track ...
... track feeder system is one in which the return feeders are electrically in parallel with the tracks . Under such circum- stances the cables may be operating very inefficiently as current conductors and as a means of reducing track ...
Halaman
... track rails are connected to the negative bus at the nearest convenient point . Conductors are here regarded as in parallel with the rails when one end is connected to the track and the other to a station bus - bar which is connected ...
... track rails are connected to the negative bus at the nearest convenient point . Conductors are here regarded as in parallel with the rails when one end is connected to the track and the other to a station bus - bar which is connected ...
Halaman
... tracks shall be known to be in the best possible condition , especially in regard to the joints . whose resistance should not exceed , in each case , that of 10 meters of the normal track . The management is required to verify ...
... tracks shall be known to be in the best possible condition , especially in regard to the joints . whose resistance should not exceed , in each case , that of 10 meters of the normal track . The management is required to verify ...
Isi
Large TurboGenerator Units | 17 |
Condensers | 25 |
Power House Auxiliaries | 34 |
18 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current amperes apparatus auxiliaries boiler room brick cable capacity chemical circuit coal Committee commutator Company condenser conductor connected construction copper corrosion current transformers Curve Demand Meters determined device direct current drop earth efficiency Elec electric railway electrolysis Engineers equipment feed water feeders frazil ice frequency heat higher inches increase indication induction installation instrument insulation joints kilowatts kv-a load loss machine main unit manufacturers measurements mechanical metal method motor National Electric Code operation oxidation percent pipe plant potential pounds power factor practice present pump rails rated ratio reactance regulation resistance Section soda ash specific speed standard steam pressure steam turbine stoker storage stray currents structures superheat supply surface surface condensers switch temperature tion track transformers tube turbine volt-amperes voltage volts watthour meter Wattmeter windings wire