Convention, Bagian 3 |
Dari dalam buku
Hasil 1-3 dari 79
Halaman x
... necessary the development of equipment for high - voltage dis- tribution service . Distribution voltages up to at least 15 000 volts are necessary at the present time . The intention of the Overhead Line Committees was to formu- late ...
... necessary the development of equipment for high - voltage dis- tribution service . Distribution voltages up to at least 15 000 volts are necessary at the present time . The intention of the Overhead Line Committees was to formu- late ...
Halaman 754
... necessary protection from injury thereto must be provided by the Contractor , and if necessary to make any changes thereto same must be made entirely by the Contractor and to the approval of the Owners , payment for same to be agreed ...
... necessary protection from injury thereto must be provided by the Contractor , and if necessary to make any changes thereto same must be made entirely by the Contractor and to the approval of the Owners , payment for same to be agreed ...
Halaman 755
... necessary to secure compliance with the same . ( 30 ) The Engineer shall determine all questions that may arise in regard to lines , levels , locations , dimensions , materials and work- manship . ( 31 ) If in the opinion of the ...
... necessary to secure compliance with the same . ( 30 ) The Engineer shall determine all questions that may arise in regard to lines , levels , locations , dimensions , materials and work- manship . ( 31 ) If in the opinion of the ...
Isi
INTRODUCTION | 3 |
SHUNT STANDARDIZATION Data | 15 |
RECENT DEVELOPMENTS | 39 |
3 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
3-phase Alternating Current alternating-current ammeter amperes apparatus boiler cable capacity cent Chairman circuit coal coil Committee condenser conductor connected construction cost current transformers DEMAND INDICATOR designed device direct current distribution diversity factor duct economizer Edison Elec Electric Company engine equipment feeder Francis turbine fuel fuses gates governor effort ground hydro-electric inductive industry installation instrument insulators kilowatts lamps Light & Power lightning arresters load machine manholes manufacturers maximum ment method miles motor oil switches operation Overhead Line Pacific panels phase pipe plant polyphase Power Company practice present pressure pump railway regulation rheostat rules safety secondary short-circuit shunt single-phase standard station steam street substation supply surface condenser switchboard synchronous condensers temperature tion trans transmission turbine unit Utah voltage voltmeter volts water power water wheel water-power watthour meter wattmeter Westinghouse wire