... power plant . Near the front of the power house would be installed eight or ten 12,000 - volt , 3 - phase , 25 - cycle electric generators , each di- rectly coupled to double horizontal hydraulic turbines of 10,000- hp to 12,000 - hp ...
... power plant . Near the front of the power house would be installed eight or ten 12,000 - volt , 3 - phase , 25 - cycle electric generators , each di- rectly coupled to double horizontal hydraulic turbines of 10,000- hp to 12,000 - hp ...
Halaman 179
... power house itself contains 11,000 kv - a in generators , arranged in seven 60 - cycle , 2200 - volt units . Energy is transmitted from the plant at an e.m.f. of 34,600 volts obtained from transformer banks in an- other building . The ...
... power house itself contains 11,000 kv - a in generators , arranged in seven 60 - cycle , 2200 - volt units . Energy is transmitted from the plant at an e.m.f. of 34,600 volts obtained from transformer banks in an- other building . The ...
Halaman 180
... Power Supply Company , Lta . , Bombay , supplies electrical energy in Bombay , principally for motors in cotton ... house , a distance of 13,000 ft , in which length there is a fall of 1725 ft . The power house is situated at a place ...
... Power Supply Company , Lta . , Bombay , supplies electrical energy in Bombay , principally for motors in cotton ... house , a distance of 13,000 ft , in which length there is a fall of 1725 ft . The power house is situated at a place ...
Isi
PAGE | 5 |
INDICATING INSTRUMENT METHODS FOR TESTING CURRENT | 11 |
TWO WATTHOUR METER METHOD OF TESTING INSTRUMENT | 26 |
23 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
Accident Prevention alternating current ammeter amperes apparatus belt boiler Bureau of Standards cable capacity cent Central Committee central power central station Chairman Chicago circuit City coal coil compound condenser conductors connected considerable construction cost current transformers deg fahr Diesel distribution duct efficiency electrification Employees energy engine equipment finger furnace fuse glove hydro-electric inches increase installed instrument transformers insulation interest joint lamps lightning arresters load manhole manufacturers member companies ment method Niagara Falls obtained operation Organization Overhead Line phase angle plants poles potentiometer Power Company power house practice present pressure primary pump railroad railway ratio recommendations rheostat River rubber secondary Secretary steam steam turbine stoker street substation supply temperature terminals TESCO tion trans transmission trouble tubes turbine United utilized voltage voltmeter volts water power water-power watthour meters wattmeter wire