Bidang tersembunyi
Buku Buku
" Contrary to a common assumption, the results show that when forced to maximum power, the large boilers delivered as much steam per unit area of heating surface as the small ones. 2. At maximum power, a majority of the boilers tested delivered 12 or more... "
The Elements of Railroad Engineering - Halaman 142
oleh William G. Raymond - 1913 - 405 halaman
Tampilan utuh - Tentang buku ini

Report of Proceedings of the ... Annual Convention of the ..., Volume 39

American Railway Master Mechanics' Association - 1906 - 662 halaman
...power, the large boilers delivered as much steam per unit area of heating surface as the small ones. 2. At maximum power, a majority of the boilers tested...horsepower per square foot of heating surface are 0.34, 0.40 and 0.47, respectively. 3. The two boilers holding the first and second places with respect...
Tampilan utuh - Tentang buku ini

Locomotive Cyclopedia of American Practice

1906 - 692 halaman
...power, the large boilers delivered as much steam per unit area of heating surface as the small ones. 2. At maximum power, a majority of the boilers tested...boiler horse-power per square foot of heating surface arc 0.34, 0.40 and 0.47, respectively. 3. The two boilers holding the first and second place with respect...
Tampilan utuh - Tentang buku ini

Transactions of the American Society of Mechanical ..., Volume 1-25;Volume 27

American Society of Mechanical Engineers - 1906 - 1824 halaman
...power the large boilers delivered as much steam per unit area of heating surface as the small ones. 2. At maximum power, a majority of the boilers tested...point of size, delivered 16.3 pounds. These values RUNNING CONDITIONS. BOILER PERFORMANCE. POWER. WATER ANP FUEL CONSUMPTION. POUNDS. 1 *&* o 1 power....
Tampilan utuh - Tentang buku ini

Locomotive Dictionary: An Illustrated Vocabulary of Terms which Designate ...

George Little Fowler, American Railway Master Mechanics' Association - 1906 - 692 halaman
...power, the large boilers delivered as much steam per unit area of healing surface as the small ones. 2. At maximum power, a majority of the boilers tested...heating surface per hour; two delivered more than M pounds, and one, the second in point of si/e, delivered lii.-'! pounds. These values expressed in...
Tampilan utuh - Tentang buku ini

Locomotive Cyclopedia of American Practice

1909 - 714 halaman
...power, the large boilers delivered as much steam per unit area of heating surface as the small ones. 2. At maximum power, a majority of the boilers tested...horse-power per square foot of heating surface are 0.34, 0.40 and 0.47, respectively. 3. The two boilers holding the first and second place with respect...
Tampilan utuh - Tentang buku ini

Locomotive Catechism: A Practical and Complete Work on the Locomotive ...

Robert Grimshaw - 1911 - 886 halaman
...when forced to maximum power, deliver as much steam per unit area of heating surface as small ones. At maximum power, a majority of the boilers tested...heating surface per hour; two delivered more than 14; the second largest delivered 16.3. These values, in boiler horse-power per square foot of heating surface,...
Tampilan utuh - Tentang buku ini

The Elements of Railroad Engineering

William G. Raymond - 1913 - 496 halaman
...not exceeding 21,000 pounds; while 100pound rails will permit driver loads of 30,000 pounds. Modem locomotives generally range between 21,000 and 24,500...horse-power per square foot of heating surface are o. 34, o. 40, and o. 47 respectively. The evaporative efficiency is generally maximum when the power...
Tampilan utuh - Tentang buku ini

The Elements of Railroad Engineering

William G. Raymond - 1914 - 458 halaman
...tractive effort is given in pounds, the heating surface H being given in square feet, and the speed 5 in miles per hour. Cylinder tractive effort is given...horse-power per square foot of heating surface are o. 34, o. 40, and o. 47 respectively. The evaporative efficiency is generally maximum when the power...
Tampilan utuh - Tentang buku ini

Engineering of Power Plants

Robert Heywood Fernald, George Alexander Orrok - 1916 - 626 halaman
...surface as the small ones. 2. At maximum power, a majority of the boilers tested delivered 12 or more Ib. of steam per square foot of heating surface per hour; two delivered more than 14 Ib.; and one, the second in point of size, delivered 16.3 Ib. These values expressed in terms of boiler...
Tampilan utuh - Tentang buku ini

Engineering of Power Plants

Robert Heywood Fernald, George Alexander Orrok - 1916 - 612 halaman
...power the large boilers delivered as much steam per unit area of heating surface as the small ones. 2. At maximum power, a majority of the boilers tested delivered 12 or more Ib. of steam per square foot of heating surface per hour; two delivered more than 14 Ib.; and one,...
Tampilan utuh - Tentang buku ini