... furnace is to so regulate the gas and air that a blue flame two to three inches long emerges from the top of the furnace . Temperature Measurements Any form of accurate pyrometer skilfully handled will give good results . The sight hole ...
... furnace is to so regulate the gas and air that a blue flame two to three inches long emerges from the top of the furnace . Temperature Measurements Any form of accurate pyrometer skilfully handled will give good results . The sight hole ...
Halaman 374
... furnace must neces- sarily be much slower . The reason why we use the slow rates for the electric furnace is to allow plenty of time for softening reactions to approach equilibrium . To get that equilibrium in a gas furnace would ...
... furnace must neces- sarily be much slower . The reason why we use the slow rates for the electric furnace is to allow plenty of time for softening reactions to approach equilibrium . To get that equilibrium in a gas furnace would ...
Halaman 408
... furnace temperatures are sufficiently high this slag will run , while with lower tempera- tures it becomes a gummy spongy mass which adheres to the side walls and other parts of the furnace and interferes with the proper operation of ...
... furnace temperatures are sufficiently high this slag will run , while with lower tempera- tures it becomes a gummy spongy mass which adheres to the side walls and other parts of the furnace and interferes with the proper operation of ...
Isi
INTRODUCTION | 7 |
TWO WATTMETER METHOD FOR TESTING CURRENT TRANS | 13 |
Two WATTHOUR METER METHOD OF TESTING INSTRUMENT | 26 |
25 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
Accident Prevention alternating current ammeter amperes apparatus belt boiler Bureau of Standards cable capacity cent Central Committee central power central station Chairman Chicago circuit City coal coil compound condenser conductors connected considerable construction cost current transformers deg fahr distribution duct efficiency electrification Employees energy equipment finger furnace fuse glove hydro-electric inches increase installed instrument transformers insulation interest joint lamps lightning arresters load manhole manufacturers member companies ment method Niagara Falls obtained operation Organization Overhead Line phase angle plants poles potentiometer Power Company power house practice present pressure primary pump railroad railway ratio recommendations rheostat River rubber Safety Code secondary Secretary steam steam turbine stoker street substation supply temperature terminals TESCO tion trans transmission trouble tubes turbine United utilized voltage voltmeter volts water power water-power watthour meters wattmeter wire