Elements of Fuel Oil and Steam Engineering: A Practical Treatise Dealing with Fuel Oil, for the Central Station Man, the Power Plant Operator, the Mechanical Engineer and the StudentMcGraw-Hill, 1921 - 466 halaman |
Dari dalam buku
Hasil 1-5 dari 72
Halaman xvi
... losses in steam power generation - Loss of draft in boilers- Loss in flues and turns - Total available draft required - Artificial draft . CHAPTER XXXI PAGE 251 265 CHIMNEY GAS ANALYSIS The taking of the flue gas samples and analysis ...
... losses in steam power generation - Loss of draft in boilers- Loss in flues and turns - Total available draft required - Artificial draft . CHAPTER XXXI PAGE 251 265 CHIMNEY GAS ANALYSIS The taking of the flue gas samples and analysis ...
Halaman xvii
... Loss due to moisture in the fuel - Loss due to moisture formed by burning hydrogen - Loss due to heat carried away in dry gas- Loss due to incomplete combustion - Loss due to evaporating steam for atomization - Loss due to superheating ...
... Loss due to moisture in the fuel - Loss due to moisture formed by burning hydrogen - Loss due to heat carried away in dry gas- Loss due to incomplete combustion - Loss due to evaporating steam for atomization - Loss due to superheating ...
Halaman xviii
... loss in superheater - Varying draft - Ratio of oil and steam pressures - Radiation test - Swinging load - Starting up cold - Tests on flow of oil through burners - Influence of load on pressures of oil and atomizing steam in oil burners ...
... loss in superheater - Varying draft - Ratio of oil and steam pressures - Radiation test - Swinging load - Starting up cold - Tests on flow of oil through burners - Influence of load on pressures of oil and atomizing steam in oil burners ...
Halaman 1
... there should be no excessive loss in distribution , these concentrated steam power units are usually found in the FIG . 2. - Exterior view Long Beach Plant ,. 1 CHAPTER I PAGE THE MODERN POWER PLANT FOR FUEL OIL CONSUMPTION.
... there should be no excessive loss in distribution , these concentrated steam power units are usually found in the FIG . 2. - Exterior view Long Beach Plant ,. 1 CHAPTER I PAGE THE MODERN POWER PLANT FOR FUEL OIL CONSUMPTION.
Halaman 36
... loss of heat in the hot sub- stance is evidently equal to the heat gained by the water . Let , tz be the unknown temperature of the hot substance , M , the weight of the hot substance in lb. , M , the weight of the water in lb. t2 the ...
... loss of heat in the hot sub- stance is evidently equal to the heat gained by the water . Let , tz be the unknown temperature of the hot substance , M , the weight of the hot substance in lb. , M , the weight of the water in lb. t2 the ...
Isi
1 | |
14 | |
22 | |
31 | |
50 | |
57 | |
66 | |
73 | |
235 | |
241 | |
251 | |
265 | |
271 | |
279 | |
286 | |
302 | |
78 | |
86 | |
95 | |
107 | |
124 | |
135 | |
141 | |
147 | |
155 | |
166 | |
189 | |
202 | |
221 | |
313 | |
320 | |
337 | |
351 | |
368 | |
386 | |
400 | |
411 | |
415 | |
434 | |
444 | |
Edisi yang lain - Lihat semua
Istilah dan frasa umum
absorbed ascertain barrel Baumé Baumé scale boiler efficiency boiler horsepower boiler test California calorimeter capacity carbon dioxide carbon monoxide cent chapter coal combustion compute condenser damper determined diameter draft dry saturated steam economizer Electric energy equivalent evaporation excess air feed water flame flash point flue gas formula fuel oil furnace heater heating value Hence hour hydrogen hydrometer inches installed latent heat load loss measured mechanical atomizing burners mercury method moisture nitrogen obtained oil burned oil burners oil fired oil pressure orifice Orsat oxygen pass plate pound of fuel pound of oil pound of water power plant practice pump reading regulating riveted sample saturated steam scale shown Southern California Edison specific gravity stack standard steam atomizing burners steam engineering steam pressure steam tables storage tanks superheat superheated steam supply temperature thermometer total heat tubes turbine V₁ valve weight
Bagian yang populer
Halaman 5 - To every action there is always an equal and contrary reaction ; or the mutual actions of any two bodies are always equal and oppositely directed.
Halaman 5 - Every body continues in its state of rest or of uniform motion in a straight line, except in so far as it may be compelled by impressed forces to change that state.
Halaman 406 - Earthwork embankments shall be firmly and compactly built of good earth from which stones, vegetable matter, etc., have been removed, and shall have a flat section at...
Halaman 217 - C.) to the weight of an equal volume of distilled water at the same temperature, both weights being corrected for the buoyancy of air.
Halaman 409 - Tanks located underground shall have top of tank at least three feet below the surface of the ground, and below the level of the lowest pipe in the building to be supplied. Tanks may be permitted underneath a building if buried at least three feet below the lowest floor. Tanks shall be set on a firm foundation and surrounded with soft earth or sand, well tamped into place or encased in concrete.
Halaman 120 - The name and location of the refinery, if the oil has been refined at all. "13. The fuel oil is to be delivered fob cars or vessel, according to the manner of shipment, at such places, at such times, and in such quantities as may be required, during the fiscal year ending.
Halaman 405 - Rules and Requirements of the National Board of Fire Underwriters for the Installation of Electric Wiring, as Recommended by the Underwriters' National Electrical Association.
Halaman 120 - Allen proposes the following specifications for fuel oil to be purchased by the government : (1) In determining the award of a contract, consideration will be given to the quality of the fuel offered by the bidders, as well as the price, and should it appear to be to the best interest of the Government to award a contract at a higher price than that named in the lowest bid or bids received, the contract will be so awarded. (2) Fuel oil should be either a natural homogeneous oil or a homogeneous residue...
Halaman 414 - Control valves shall be provided with stuffing box of liberal size, containing a removable cupped gland designed to compress the packing against the valve stem and arranged so as to facilitate removal. Valves shall be designed to close against the supply, and to prevent withdrawal of stem by continued operation of the handwheel. Packing affected by the oil or by heat shall not be used.
Halaman 120 - It is understood that the fuel oil delivered during the term of the contract shall be of the quality specified. The frequent or continued failure of the contractor to deliver oil of the specified quality will be considered sufficient cause for the cancellation of the contract.