NBFU Pamphlet, Masalah 53 |
Dari dalam buku
Hasil 1-5 dari 13
Halaman
... West Adams Street , Chicago , Ill . Merchants Exchange Building , San Francisco , Calif . EDITION OF 1926 Printed in U. S. A. NIV OF MICH NOTE This pamphlet supersedes the Standards for the Installation ,. Front Cover.
... West Adams Street , Chicago , Ill . Merchants Exchange Building , San Francisco , Calif . EDITION OF 1926 Printed in U. S. A. NIV OF MICH NOTE This pamphlet supersedes the Standards for the Installation ,. Front Cover.
Halaman 1
... UNDERWRITERS 85 John Street , New York , N. Y. 222 West Adams Street , Chicago , Ill . Merchants Exchange Building , San Francisco , Calif . EDITION OF 1926 TH 9111 N278 N27 DEFINITIONS In these standards the following STANDARDS ...
... UNDERWRITERS 85 John Street , New York , N. Y. 222 West Adams Street , Chicago , Ill . Merchants Exchange Building , San Francisco , Calif . EDITION OF 1926 TH 9111 N278 N27 DEFINITIONS In these standards the following STANDARDS ...
Halaman 3
... building , under ground , at least 10 feet removed from all buildings , and the top thereof shall be below the level of the lowest pipe in the building used in connection with the apparatus . b . Shall be located well below the frost ...
... building , under ground , at least 10 feet removed from all buildings , and the top thereof shall be below the level of the lowest pipe in the building used in connection with the apparatus . b . Shall be located well below the frost ...
Halaman 4
... building open- ing . f . Fill pipe shall be screened and shall terminate in a metal box or casting provided with means for locking , and when installed in the vicinity of a build- ing shall not be located within five feet of any door or ...
... building open- ing . f . Fill pipe shall be screened and shall terminate in a metal box or casting provided with means for locking , and when installed in the vicinity of a build- ing shall not be located within five feet of any door or ...
Halaman 5
... building and terminate in an approved hood located out of reach and never within less than three feet , measured horizontally and vertically , from any win- dow or other building opening . 4. Pressure Regulator . Shall be installed ...
... building and terminate in an approved hood located out of reach and never within less than three feet , measured horizontally and vertically , from any win- dow or other building opening . 4. Pressure Regulator . Shall be installed ...
Edisi yang lain - Lihat semua
Istilah dan frasa umum
accessible brass wire accessible for purposes air intake areaway where vapors artificial light authorities having jurisdiction brass or equivalent burner gauze CLASS cleaning or repairs cleaning valve COMMON GENERATOR SYSTEMS condensation connection controlling valves Distributing Pipes equivalent non-corrodible metal feet fill pipe fire protection viewpoint frost line Gasoline gas machines Gasoline Vapor Gas horizontal pipe individual generator systems initially heated INSIDE CARBURETERS joists Lamps and Systems less than 20 lineal inch liquid gasoline located long screws loose flammable material Metal heat deflectors National Electrical Code never within less Portable Lamps Pressure Lamps Pressure Supply pump purposes of cleaning reaching the shut-off readily accessible brass regu regulating or cleaning required while filling rigidly observed Rule 30 screws or bolts shut-off valve standard full-weight stantial threaded fittings Stationary and Portable Strainers supply pipe Supply Tank tank or carbureter TANKS AND INSIDE tween the burner untrapped VAPOR GAS MACHINES vapors could collect wall water sealed
Bagian yang populer
Halaman 7 - Never install more than the equivalent of the number of half-foot burners for which the machine is rated. 8. Never test the generator or piping for leaks with a flame, and never apply flame to an outlet from which the burner has been removed. 9. Never use a lighted match, lamp, candle, lantern or any other open light near the machine.
Halaman 4 - Shall be provided with a permanently open vent or with a combination fill and vent fitting so arranged that the fill pipe cannot be opened without opening the vent pipe.
Halaman 8 - No artificial heat other than hot water or steam shall be used to produce rapid evaporation, and in all such cases heating and evaporating chambers shall be entirely separate. 10. Gasoline Feed Pump. If of the simple plunger type, shall have check valves as close to the pump as convenient, and stuffing boxes shall be kept tight and free from leakage. 11. Piping and Fittings. Follow the same requirements as given under Class A, except in the following particulars: *S« Flammable Liquids Ordinance...
Halaman 5 - Department, but which shall end at least 12 feet above level of source of supply and in a location remote from fire escapes and never nearer than three feet, measured horizontally and vertically, from any window or other opening; the tank vent pipe shall terminate in a goose-neck protected in the outer end by a 30 x 30 mesh or equivalent brass wire screen.
Halaman 4 - Vent openings shall be screened (40 mesh per lineal inch brass or equivalent non-corrodible metal) and shall provide sufficient area for allowing proper flow of liquid during the filling operation. A permanently open vent pipe shall be provided with a weatherproof hood and shall terminate at a point at least twelve feet above the top of the fill pipe and never within less than three feet, measured horizontally and vertically, from any window or other building opening. (/) Fill pipe shall be screened...
Halaman 1 - Systems as recommended by the NATIONAL FIRE PROTECTION ASSOCIATION NATIONAL BOARD OF FIRE UNDERWRITERS 85 John Street, New York, NY 222 West Adams Street, Chicago, 111. Merchants Exchange Building, San Francisco, Calif. EDITION OF 1926 £*•• TM NVI DEFINITIONS In these standards the following words are used as defined below: "Shall" is intended to indicate requirements.
Halaman 15 - These lamps are regarded from a fire protection viewpoint as more dangerous than the systems covered in Class A, Class B or Class C, and where used their hazards should be recognized. If their use is permitted, the following general specifications for regulating the same should be observed : 24.
Halaman 14 - Should preferably be attached to an outside wall and so installed that a clear space is maintained above and below from floor to ceiling, and for at least a foot on either side of the device. NOTE: Where located against other than a fire-resistive wall, shall be insulated therefrom by an ample sheet of metal placed not less than 1 inch from the wall, leaving an air space. (c) Shall be located so that no artificial light will be required while filling...
Halaman 10 - A readily accessible brass wire gauze having a mesh of at least 40 per lineal inch, or its equivalent, shall be provided between the service pipe and the machine. CLASS C. GASOLINE LIGHTING SYSTEMS HAVING OUTSIDE TANKS AND INSIDE FLAME-HEATED GENERATORS. These systems are regarded from a fire protection viewpoint as more dangerous than the systems in Class A or Class B. Where used, their hazards should be recognized and the following rules and precautions rigidly observed : 12. Supply Tank. (a) Gasoline...
Halaman 6 - Connections to outside tank shall not be located near nor placed in the same trench with other piping. c. Openings for pipes through outside walls shall be securely cemented and made water and oil-tight.