... building temperature which passes out , by whatever means , a cubic foot of outside air must come in and this must be raised to the inside temperature . Where no particular provisions are made for introducing fresh air into a building ...
... building temperature which passes out , by whatever means , a cubic foot of outside air must come in and this must be raised to the inside temperature . Where no particular provisions are made for introducing fresh air into a building ...
Halaman 767
... building constant and in order to determine the amount of heat which must be supplied during the heating season it is merely necessary to multiply this building constant by the number of hours in the heating season and the average ...
... building constant and in order to determine the amount of heat which must be supplied during the heating season it is merely necessary to multiply this building constant by the number of hours in the heating season and the average ...
Halaman 770
... building , exhausting into the heating system , the maximum amount of heating which can be credited to the cost of power generation is 43.5 percent of the total . This assumes that there will always be sufficient exhaust steam for ...
... building , exhausting into the heating system , the maximum amount of heating which can be credited to the cost of power generation is 43.5 percent of the total . This assumes that there will always be sufficient exhaust steam for ...
Isi
Report of the Commercial Section | 1 |
Report of Commercial Section Finance Committee | 12 |
Report of Committee on Compensation of Salesmen | 20 |
13 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
200-watt mazda alloys amount Atlantic City NJ average BEAM boiler booklet bowl brass building campaign candlepower central station companies Chairman clock connection contractors cooking copper cost curve demand Department distribution Edison efficiency Elec electric furnace electric heating Electric Light Association electric range electric sign electrical advertising Engineering equipment factory fixtures FLOOD LIGHTING PROJECTOR foot-candles give glass illumination increased industrial lighting installation isolated plant kilowatt kilowatt-hour kw-hr load manufacturers mazda C lamps Melting point member companies merchandising metal meter method motor National Electric Light obtained operation parabolic reflectors percent pilot light possible practice profit prospect pumping question Range Committee recommend reflector revenue salesman secure selling sold standard steam steel Store Lighting Sub-Committee supply switch temperature thermal efficiency tion unit voltage volts water heater wattage watts Wiltse window wiring YORK CITY zinc