Convention, Volume 18 |
Dari dalam buku
Hasil 1-3 dari 25
Halaman 45
... losses bear at light load . Almost the whole loss of efficiency , due to variable load , is , therefore , attributable to the boiler . There is still another class of losses which is not amenable to calculation , viz . , those due to ...
... losses bear at light load . Almost the whole loss of efficiency , due to variable load , is , therefore , attributable to the boiler . There is still another class of losses which is not amenable to calculation , viz . , those due to ...
Halaman 59
... losses so fatal to economy where boilers are used . These standby losses for boilers are given by Dowson * as ten per cent ; that is to say , that boilers that are standing idle and furnishing no steam will require ten per cent of the ...
... losses so fatal to economy where boilers are used . These standby losses for boilers are given by Dowson * as ten per cent ; that is to say , that boilers that are standing idle and furnishing no steam will require ten per cent of the ...
Halaman 91
... loss of twenty - five per cent of all the energy generated ; but , as only half is stored , the loss should be but twelve and one - half per cent of the whole . Instead of dividing by .75 , he should have divided by .875 , which gives ...
... loss of twenty - five per cent of all the energy generated ; but , as only half is stored , the loss should be but twelve and one - half per cent of the whole . Instead of dividing by .75 , he should have divided by .875 , which gives ...
Isi
Active Members | 4 |
The Okonite Company Limited 297 | 8 |
Officers and Executive Committee ΙΟ | 10 |
4 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current amount amperes apparatus arc lamps arc lighting armature boilers candle-power capacity carbons cell cent central station charge circuit Cleveland committee connected convention copper curve direct current discharge disruptive discharges dynamo economy Edison Edison illuminating companies effective horse-power efficiency Electric Company Electric Light Association Electric Light Company electrical horse-power electro-motive force energy feed and steam feed storage fixed annual cost gas engine gentlemen horse-power hour illuminometer incandescent inches indicated horse-power installation instrument insulation interest Light and Power lightning arrester machine maximum measured monocyclic system motor National Electric Light operation paper PERRY plant plates polyphase system pound of coal Power Company power wire practice PRESIDENT Professor question SEELY single-phase spark gaps standard candle station battery steam storage storage battery tanks test object thermal storage vessel three-phase three-wire system to-day Total fixed annual transformers two-phase units variable load voltage volts watts