Convention, Volume 2;Volume 32 |
Dari dalam buku
Hasil 1-3 dari 79
Halaman 22
... supply head is not utilized , and sometimes the installation of cooling towers and basins . The oil- ing systems might be comparable with steam practice . Gravity feed supply systems are often installed with oil filters and supply tanks ...
... supply head is not utilized , and sometimes the installation of cooling towers and basins . The oil- ing systems might be comparable with steam practice . Gravity feed supply systems are often installed with oil filters and supply tanks ...
Halaman 24
... supply a considerable item . In operating an engine with variable load it is necessary to supply a sufficient quantity of water to both the jackets and the pistons to maintain a suitable temperature for full - load operation , and this ...
... supply a considerable item . In operating an engine with variable load it is necessary to supply a sufficient quantity of water to both the jackets and the pistons to maintain a suitable temperature for full - load operation , and this ...
Halaman 799
... supply of steam and shall not be liable for damages which may be caused the Consumer in con- sequence of the Company's failure at any time to supply steam , beyond a pro rata amount for the steam the Company fails to furnish during any ...
... supply of steam and shall not be liable for damages which may be caused the Consumer in con- sequence of the Company's failure at any time to supply steam , beyond a pro rata amount for the steam the Company fails to furnish during any ...
Isi
Conventions of the Association lxi | xiii |
Second Accounting Session | 74 |
Second Session | 134 |
12 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating-current amount Anthracite apparatus arc lamps average boiler bolts braces buckets cable capacity carbon cent central station CHAIRMAN charge circuits City coal coils committee condenser connected construction Consumer contract copper cost cross-arm curve customers discussion distribution EDISON COMPANY efficiency Elec ELECTRIC LIGHT ASSOCIATION equipment feet Figure fixture galvanized gas engine guy wire heat horse-power illumination inches increase installation insulation iron kilowatt-hour kilowatts lightning arresters Lignite line wire load factor located low-pressure machine manufacturers meter method motor motor-generator NATIONAL ELECTRIC LIGHT obtained operating overhead line paper pins pipe plant pole possible pounds power factor practice pressure producer pump Rateau reactance secondary shaft shown in Plate shows space specifications standard station load steam steel strain strain insulators supply surface condenser synchronous temperature tests tion transformers tungsten lamp turbine voltage volts watts