... substation is the ratio of the annual substation maximum of 450 kilowatts to the substation load of 90 kilowatts at 10:00 A. M. , the hour of the system maxi- mum , or 450 90 = 5 . If this substation is a part of a system such as that ...
... substation is the ratio of the annual substation maximum of 450 kilowatts to the substation load of 90 kilowatts at 10:00 A. M. , the hour of the system maxi- mum , or 450 90 = 5 . If this substation is a part of a system such as that ...
Halaman 249
... substations or wholesale users . This is very clear from the figures in the foregoing table in which substation 1 , having a load factor of 35 per cent has an individual diversity factor of 1.06 , while substation 2 , with prac- tically ...
... substations or wholesale users . This is very clear from the figures in the foregoing table in which substation 1 , having a load factor of 35 per cent has an individual diversity factor of 1.06 , while substation 2 , with prac- tically ...
Halaman 310
... substation belonging to the Southern Power Company and designed to operate on 100,000 volts was described in a paper entitled " A 100,000 - Volt Portable Substation , " by Messrs . C. I. Burkholder and Nicholas Stahl . As about 70 ...
... substation belonging to the Southern Power Company and designed to operate on 100,000 volts was described in a paper entitled " A 100,000 - Volt Portable Substation , " by Messrs . C. I. Burkholder and Nicholas Stahl . As about 70 ...
Isi
INTRODUCTION | 3 |
SHUNT STANDARDIZATION DATA | 15 |
RECENT DEVELOPMENTS | 39 |
3 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
3-phase accidents Alternating Current alternating-current ammeter amperes apparatus boiler cable capacity cent Chairman circuit coal coil Committee condenser conductor connected construction cost designed device direct current direct-current distribution diversity factor duct economizer Edison Elec Electric Company engine equipment feeder Francis turbine fuel fuses gates governor effort ground hydro-electric inches inductive industry installation instrument insulators kilowatts lamps Light & Power lightning arresters load machine manholes manufacturers maximum ment method miles motor obtained oil switches operation Overhead Line Pacific panels phase pipe plant polyphase potential transformers potentiometer Power Company practice present pressure pump railway regulation rheostat rules safety secondary short-circuit shunt single-phase standard station steam street substation supply surface condenser switchboard synchronous condensers temperature tion trans turbine unit Utah voltage voltmeter volts water power water wheel water-power watthour meter wattmeter wire