... station demand . TABLE IV ASSUMED ALTERNATING CURRENT CENTRAL STATION SYSTEM Links of Systems Generating Station Transmission System Substation Distribution Lines Transformers Meters Miscellaneous Total Group Kw Invest- Diver Useful ...
... station demand . TABLE IV ASSUMED ALTERNATING CURRENT CENTRAL STATION SYSTEM Links of Systems Generating Station Transmission System Substation Distribution Lines Transformers Meters Miscellaneous Total Group Kw Invest- Diver Useful ...
Halaman 313
... stations , but operation of the synchronous condensers at the receiving station over the range required would not be feasible without provision for a complete reduction of the exciter voltage . With 150,000 volts at the receiving end of ...
... stations , but operation of the synchronous condensers at the receiving station over the range required would not be feasible without provision for a complete reduction of the exciter voltage . With 150,000 volts at the receiving end of ...
Halaman 499
... station and a consumption in the city of approximately 9000 kilowatts , for it is not possible to keep sufficient ... station is very small in proportion to the load the station is expected to pick up in case of emergency . The ...
... station and a consumption in the city of approximately 9000 kilowatts , for it is not possible to keep sufficient ... station is very small in proportion to the load the station is expected to pick up in case of emergency . The ...
Isi
INTRODUCTION | 3 |
SHUNT STANDARDIZATION DATA | 15 |
RECENT DEVELOPMENTS | 39 |
3 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
3-phase accidents Alternating Current alternating-current ammeter amperes apparatus boiler cable capacity cent Chairman circuit coal coil Committee condenser conductor connected construction cost designed device direct current direct-current distribution diversity factor duct economizer Edison Elec Electric Company engine equipment feeder Francis turbine fuel fuses gates governor effort ground hydro-electric inches inductive industry installation instrument insulators kilowatts lamps Light & Power lightning arresters load machine manholes manufacturers maximum ment method miles motor obtained oil switches operation Overhead Line Pacific panels phase pipe plant polyphase potential transformers potentiometer Power Company practice present pressure pump railway regulation rheostat rules safety secondary short-circuit shunt single-phase standard station steam street substation supply surface condenser switchboard synchronous condensers temperature tion trans turbine unit Utah voltage voltmeter volts water power water wheel water-power watthour meter wattmeter wire