Convention, Volume 42;Volume 73 |
Dari dalam buku
Hasil 1-3 dari 82
Halaman 153
... MAXIMUM OUTPUT FROM HYDRO - ELECTRIC PLANTS War - time demand for power was responsible for a number of improvements ... maximum possible number of hours . 2. Adjusting gate operating mechanism in such a manner that wide open condition ...
... MAXIMUM OUTPUT FROM HYDRO - ELECTRIC PLANTS War - time demand for power was responsible for a number of improvements ... maximum possible number of hours . 2. Adjusting gate operating mechanism in such a manner that wide open condition ...
Halaman 168
... maximum of 190,000 kw .; the 59th Street Station , upon completion of the present turbines , at 195,000 kw . with a maximum of 210,000 kw . , using as our basic unit 30,000 kw . When consideration is given to the capacity of the plants ...
... maximum of 190,000 kw .; the 59th Street Station , upon completion of the present turbines , at 195,000 kw . with a maximum of 210,000 kw . , using as our basic unit 30,000 kw . When consideration is given to the capacity of the plants ...
Halaman 379
... maximum torque relay will lift , operating the maximum torque switch which inserts the proper resistance in motor secondary to give the maximum torque . The motor may stall , but remains connected to the line , exerting its maximum ...
... maximum torque relay will lift , operating the maximum torque switch which inserts the proper resistance in motor secondary to give the maximum torque . The motor may stall , but remains connected to the line , exerting its maximum ...
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current amperes apparatus automatic auxiliary boiler cable capacity cent central station Chairman circuit breaker clinker coal coils combustion Committee condenser connection construction cost delta connection devices direct current distribution transformers drive duct economizer efficiency ejector Electric Company Electric Light engineers equipment experience fahr feed water fire fuel furnace fuses galvanometer heat Hydro-Electric increased induction motor installation insulation joint kv-a lignites load low voltage machine manholes manufacturers maximum member companies meter method motor nozzles obtained operating Overhead Lines pipe plant polarity potential transformers Power Company power factor power factor correction practice Prime Movers pump reactance rotary converter Section speed standard steam turbine steel stoker sub-bituminous coals substations superheater switch synchronous synchronous condenser telephone temperature testers three phase tion trans trouble tubes turbine units valve volt voltage rating volts waterbacks welding winding