Convention, Volume 42;Volume 73 |
Dari dalam buku
Hasil 1-3 dari 87
Halaman 45
... heat equivalent of the mechanical work done . It also loses some heat due to the discharge of steam and heated air from the condenser . The steam ejector can discharge into a surge tank , and thus recover practically all the heat that ...
... heat equivalent of the mechanical work done . It also loses some heat due to the discharge of steam and heated air from the condenser . The steam ejector can discharge into a surge tank , and thus recover practically all the heat that ...
Halaman 139
... HEAT AVAILABLE IN ADIABATIC EXPANSION FROM VARIOUS PRESSURES TO 29 VAC REFD . WITH CONSTANT TOTAL HEAT CONTENTS IN HIGH PRESSURE STEAM . ALSO RESULTANT IDEAL WATER RATE AND R. C. EFF AT 45,000 KW . LOAD . 480 470 460 450 440 1320 BTU TOTAL ...
... HEAT AVAILABLE IN ADIABATIC EXPANSION FROM VARIOUS PRESSURES TO 29 VAC REFD . WITH CONSTANT TOTAL HEAT CONTENTS IN HIGH PRESSURE STEAM . ALSO RESULTANT IDEAL WATER RATE AND R. C. EFF AT 45,000 KW . LOAD . 480 470 460 450 440 1320 BTU TOTAL ...
Halaman 188
... heat in the furnace and the water passing through this type of waterbacks absorbed 41⁄2 to 5 per cent of the total heat generated in the furnace . We have since changed the design of these waterbacks by shortening them to 3 feet in ...
... heat in the furnace and the water passing through this type of waterbacks absorbed 41⁄2 to 5 per cent of the total heat generated in the furnace . We have since changed the design of these waterbacks by shortening them to 3 feet in ...
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current amperes apparatus automatic auxiliary boiler cable capacity cent central station Chairman circuit breaker clinker coal coils combustion Committee condenser connection construction cost delta connection devices direct current distribution transformers drive duct economizer efficiency ejector Electric Company Electric Light engineers equipment experience fahr feed water fire fuel furnace fuses galvanometer heat Hydro-Electric increased induction motor installation insulation joint kv-a lignites load low voltage machine manholes manufacturers maximum member companies meter method motor nozzles obtained operating Overhead Lines pipe plant polarity potential transformers Power Company power factor power factor correction practice Prime Movers pump reactance rotary converter Section speed standard steam turbine steel stoker sub-bituminous coals substations superheater switch synchronous synchronous condenser telephone temperature testers three phase tion trans trouble tubes turbine units valve volt voltage rating volts waterbacks welding winding