... ground , it must be broken down by applying a sufficiently high voltage . The fault localizer is then connected to the faulty conductor and a good parallel conductor . At the other end these two con- ductors are joined . The localizer ...
... ground , it must be broken down by applying a sufficiently high voltage . The fault localizer is then connected to the faulty conductor and a good parallel conductor . At the other end these two con- ductors are joined . The localizer ...
Halaman 221
... grounds . Outside Grounds Very few of the companies ground their neutral intentionally outside substations , though some ground to junction box castings . Some are accidentally grounded to a greater or less extent by the use of bare or ...
... grounds . Outside Grounds Very few of the companies ground their neutral intentionally outside substations , though some ground to junction box castings . Some are accidentally grounded to a greater or less extent by the use of bare or ...
Halaman 250
... ground desired . If there are any weak spots , these break down to ground but the generator being constant - current there is no seriously destructive short circuit . This method is evidently not possible with a multi - conductor cable ...
... ground desired . If there are any weak spots , these break down to ground but the generator being constant - current there is no seriously destructive short circuit . This method is evidently not possible with a multi - conductor cable ...
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current amperes apparatus automatic auxiliary boiler cable capacity cent central station Chairman circuit breaker clinker coal coils combustion Committee condenser connection construction cost delta connection devices direct current distribution transformers drive duct economizer efficiency ejector Electric Company Electric Light engineers equipment experience fahr feed water fire fuel furnace fuses galvanometer heat Hydro-Electric increased induction motor installation insulation joint kv-a lignites load low voltage machine manholes manufacturers maximum member companies meter method motor nozzles obtained operating Overhead Lines pipe plant polarity potential transformers Power Company power factor power factor correction practice Prime Movers pump reactance rotary converter Section speed standard steam turbine steel stoker sub-bituminous coals substations superheater switch synchronous synchronous condenser telephone temperature testers three phase tion trans trouble tubes turbine units valve volt voltage rating volts waterbacks welding winding