Convention, Volume 2;Volume 34;Volume 41 |
Edisi yang lain - Lihat semua
Istilah dan frasa umum
accuracy adjustment amount AMPERES apparatus arc lamps attachments average bills brush cable capacity cent central stations CHAIRMAN charge circuit Clause coal-tar coils Committee commutator condenser conductor connection construction consumer copper cost cover creosote creosote oil crossarms cubic foot customers depreciation discount Douglas fir engineers expense Fahrenheit feet full load ground high-tension inches increase INDUCTION METER inspection installation installation test insulation invoice jewel kilowatt-hour kilowatts lamps ledger less Light and Power light load Lighting Company located low-tension windings machine magnets material ment method month obtained open-tank operating Osage orange Overhead Line paper pins placed PLATE poles potential power-factor practically purchasing railway record rotary converters secondary Section short-circuit shown specifications standard steam storeroom strain insulators telephone tension timber tion torque transformer treated treatment Tungsten voltage voltmeter volts voucher wires
Bagian yang populer
Halaman 477 - Oklahoma, hereinafter sometimes called " trustee," party of the second part. Whereas the party of the first part...
Halaman 181 - Accrued Amortization of Capital.'" "Note A. Until otherwise ordered, the 'amount estimated to be necessary to cover such wear and tear and obsolescence and inadequacy as have accrued during any month shall be based on a rule determined by the accounting corporation.
Halaman 388 - As soon as the stronger solution is taken from the vessel containing the unfiltered neutralized stock solution, additional crystals and water must be added to the stock solution. An excess of cupric oxide shall always be kept in the unfiltered stock solution. Quantity of Solution.
Halaman 539 - Solution shall not be used for more than one series of four immersions. E. SAMPLES. — Not more than seven wires shall be simultaneously immersed and not more than one sample of galvanized material other than wire shall be immersed in the specified quantity of solution. The samples shall not be grouped or twisted together, but shall be well separated so as to permit the action of the solution to be uniform upon all immersed portions of the samples.
Halaman 522 - The conductors shall be considered as uniformly loaded throughout their length, with a load equal to the resultant of the dead load plus the weight of a layer of ice...
Halaman 253 - Inspector shall order the gas or electrical corporation forthwith to remove the same and to place instead thereof a correct meter, and the...
Halaman 379 - Pine, to cover what is known as "red pine." 4. Hemlock, to cover Southern or Eastern hemlock; that is, hemlock from all States east of and including Minnesota. 5. Western Hemlock, to cover hemlock from the Pacific Coast.
Halaman 981 - ... imposed by them, shall provide for improving and developing navigation, and fix such charge or charges for the privilege granted as may be sufficient to restore conditions with respect to navigability as existing at the time such privilege be granted or reimburse the United States for doing the same, and for such additional or further expense as may be incurred by the United States with...
Halaman 492 - ... wire and of a size not less than No. 12 B. & S. gauge for a single wire and No. 14 B. & S. gauge for each wire of a twisted pair. Where the crossarms carrying the electric light wires...
Halaman 388 - ... of 36 parts, by weight, of crystals to 100 parts, by weight, of water. The solution shall be neutralized by the addition of an excess of chemically pure cupric oxide (Cu O).