Halaman 332
... relay equipments de- signed to reclose a circuit breaker immediately after it opens on overload . Should the circuit breaker reopen , it will again be re- closed for a total of three operations , all of which take place within a few ...
... relay equipments de- signed to reclose a circuit breaker immediately after it opens on overload . Should the circuit breaker reopen , it will again be re- closed for a total of three operations , all of which take place within a few ...
Halaman 333
... Relay Type CT Amps Nyla No. Serial No. CIRCUIT BREAKERS Current in Restoring Relay . -Service Restored . Short -. FIG . 26 - TYPE CV VOLTAGE RELAY ADJUSTED FOR USE AS A LIMITING RELAY FIG . 27 - HESITATING CONTROL RELAY FOR AUTOMATIC ...
... Relay Type CT Amps Nyla No. Serial No. CIRCUIT BREAKERS Current in Restoring Relay . -Service Restored . Short -. FIG . 26 - TYPE CV VOLTAGE RELAY ADJUSTED FOR USE AS A LIMITING RELAY FIG . 27 - HESITATING CONTROL RELAY FOR AUTOMATIC ...
Halaman 334
... Relay Trip Coil ยท Opened . Energized . Closing Coil Energized . Current in Closing Coil . Power removed from Trip Coil Restoring Relay Opened . FIG . 29 - OSCILLOGRAPH RECORDS SHOWING OPERATION OF SERVICE - RESTORING RELAY SYSTEM ON A ...
... Relay Trip Coil ยท Opened . Energized . Closing Coil Energized . Current in Closing Coil . Power removed from Trip Coil Restoring Relay Opened . FIG . 29 - OSCILLOGRAPH RECORDS SHOWING OPERATION OF SERVICE - RESTORING RELAY SYSTEM ON A ...
Isi
FIRST SESSIONTUESDAY MAY 20 1919 | 1 |
3Report of Committee on Prime Movers | 7 |
Discussed by W L ABBOTT Chicago 166 192 193 195 197 | 166 |
3 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current amperes apparatus automatic auxiliary boiler cable capacity cent central station Chairman circuit breaker clinker coal coils combustion Committee condenser connection considerable construction cost delta connection devices direct current distribution transformers drive duct economizer efficiency ejector Electric Company Electric Light engineers equipment experience fahr feed water fire fuel furnace fuses galvanometer heat Hydro-Electric increased induction motor inductive interference installation insulation joint kv-a lignites load machine manholes manufacturers maximum member companies meter method motor nozzles obtained oil circuit breaker operating Overhead Lines panies plant polarity potential transformers Power Company power factor power factor correction practice Prime Movers pump reactance regulators rotary converter Section speed standard steam turbine steel stoker sub-bituminous coals sub-committee substations superheater switch synchronous synchronous condenser telephone temperature testers tion trans trouble tubes turbine units valve volt volts waterbacks welding winding