... factors as maximum efficiencies , cost per kw . , and space require- ments show a ... safety , efficiency and cost , the size of systems today will hardly warrant ... factor , available running time and minimum reserve capacity . As the ...
... factors as maximum efficiencies , cost per kw . , and space require- ments show a ... safety , efficiency and cost , the size of systems today will hardly warrant ... factor , available running time and minimum reserve capacity . As the ...
Halaman 141
... safety valves on steam boilers are set has no bearing on the rates charged for steam boiler insurance . Steam boiler insuring companies require that steam boilers be so constructed and operated that they shall have a computed factor of ...
... safety valves on steam boilers are set has no bearing on the rates charged for steam boiler insurance . Steam boiler insuring companies require that steam boilers be so constructed and operated that they shall have a computed factor of ...
Halaman 308
... factor of safety in the rating than there is at present . One large manufacturer gives ratings at 20 deg . rise as well as at 30 deg . , and another rates at 30 deg . and uses a conversion factor for determining the capacity at other ...
... factor of safety in the rating than there is at present . One large manufacturer gives ratings at 20 deg . rise as well as at 30 deg . , and another rates at 30 deg . and uses a conversion factor for determining the capacity at other ...
Isi
FIRST SESSIONTUESDAY MAY 20 1919 | 1 |
3Report of Committee on Prime Movers | 7 |
Discussed by W L ABBOTT Chicago 166 192 193 195 197 | 166 |
3 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current amperes apparatus automatic auxiliary boiler cable capacity cent central station Chairman circuit breaker clinker coal coils combustion Committee condenser connection considerable construction cost delta connection devices direct current distribution transformers drive duct economizer efficiency ejector Electric Company Electric Light engineers equipment experience fahr feed water fire fuel furnace fuses galvanometer heat Hydro-Electric increased induction motor inductive interference installation insulation joint kv-a lignites load machine manholes manufacturers maximum member companies meter method motor nozzles obtained oil circuit breaker operating Overhead Lines panies plant polarity potential transformers Power Company power factor power factor correction practice Prime Movers pump reactance regulators rotary converter Section speed standard steam turbine steel stoker sub-bituminous coals sub-committee substations superheater switch synchronous synchronous condenser telephone temperature testers tion trans trouble tubes turbine units valve volt volts waterbacks welding winding