Bidang tersembunyi
Buku Buku
" Wrought Iron. All wrought iron shall be uniform in character, fibrous, tough and ductile. It shall have an ultimate tensile resistance of not less than 48,000- pounds per square inch, an elastic limit of not less than 24,000 pounds per square inch, and... "
Erection and Inspection of Iron and Steel Constructions: Written for the Use ... - Halaman 131
oleh Lupescu Morris Bernfeld - 1913 - 225 halaman
Tampilan utuh - Tentang buku ini

Engineering Contracts and Specifications: Including a Brief Synopsis of the ...

John Butler Johnson - 1895 - 444 halaman
...character, and specimens broken in a testing machine shall show a tensile strength of not less than 60,000 pounds per square inch, and an elongation of 20 per cent, in eight diameters. 10:. Finished bolts and nuts of Tobin or Phosphor bronze may be tested in the same manner...
Tampilan utuh - Tentang buku ini

Engineering Contracts and Specifications: Including a Brief Synopsis of the ...

John Butler Johnson - 1895 - 440 halaman
...character, and specimens broken in a testing machine shall show a tensile strength of not less than 60,000 pounds per square inch, and an elongation of 20 per cent. in eight diameters. io:. Finished bolts and nuts of Tobin or Phosphor bronze may be tested in the same manner...
Tampilan utuh - Tentang buku ini

A Treatise on Civil Engineering

William Macfarland Patton - 1895 - 1864 halaman
...obtained having a tensile strength of 35 tons = 78,400 pounds, and an elastic limit of 20 tons = 44,800 pounds, per square inch, and an elongation of 20 per cent in 8 inches of length. Such steel would endure a working stress of 8 tons = 17,920 pounds per square inch....
Tampilan utuh - Tentang buku ini

Proceedings of the Board of Trustees of the Sanitary District of Chicago

Chicago Sanitary District. Board of Trustees - 1898 - 808 halaman
...MATERIAL. WROUGHT IRON. Rioct Iron. в. All iron used for rivets shall have an ultimate tensile strength of not less than 48,000 pounds per square inch, an elastic limit of at least 2B. Out) pounds per square inch, and an elongation of at least twenty (20) per cent in eight...
Tampilan utuh - Tentang buku ini

Proceedings of the Board of Trustees of the Sanitary District of Chicago

Chicago Sanitary District. Board of Trustees - 1900 - 918 halaman
...presented. QUALITY OK MATERIAL. wnorOHT IKON. 6. All iron used shall have an ultimate tensile strength of not less than 48,000 pounds per square inch, an elastic limit of at least 26,000 pounds per square inch, and ¡in elongation of at least twenty (20) per cent in eight...
Tampilan utuh - Tentang buku ini

Illustrated Catalogue of Narrow-gauge Locomotives: Adapted Especially to ...

Baldwin Locomotive Works - 1900 - 464 halaman
...each heat used in filling our orders should, when tested, have an ultimate tensile strength of 80,000 pounds per square inch, and an elongation of 20 per cent., in a test section originally 2 inches long. Blooms will not be accepted that show an ultimate tensile...
Tampilan utuh - Tentang buku ini

The Building Code of the City of New York

New York (N.Y.) - 1901 - 186 halaman
...copy of the results of tests, such as he may direct shall be made. Sec. 21. — Structural Material. Wrought Iron. All wrought iron shall be uniform in...ultimate tensile resistance of not less than 48,000 Ibs. per square inch, an elastic limit of not less than 24,000 Ibs. per square inch, and an elongation...
Tampilan utuh - Tentang buku ini

Proceedings of the Board of Trustees of the Sanitary District of Chicago

Chicago Sanitary District. Board of Trustees - 1902 - 864 halaman
...may have occurred. Wrmiglit Iron. 8. All wrought iron used shall have an ultimate tensile strength of not less than 48,000 pounds per square inch, an elastic limit of at least 26,000 pounds per square inch, and an elongation of at least 20 per cent In eight inches,...
Tampilan utuh - Tentang buku ini

Cassier's Magazine, Volume 22

1902 - 744 halaman
...annealed, has been used largely for rifle and gun barrels. This steel has an elastic limit of 80,000 pounds per square inch and an elongation of 20 per cent, in test bars % inch in diameter and 2 inches long. Similar material, but differently treated, and used...
Tampilan utuh - Tentang buku ini

Building-law of the Town of Brookline, Adopted March 31, 1903, Approved by ...

Brookline (Mass.). - 1903 - 142 halaman
...of the results of tests, such as he may direct shall be made. SECT1ON 10. Structural Material. — Wrought Iron. — All wrought iron shall be uniform...24,000 pounds per square inch, and an elongation of twenty per cent. in eight inches, when tested in small specimens. Steel. — All structural steel shall...
Tampilan utuh - Tentang buku ini