Convention, Volume 5;Volume 39;Volume 62 |
Dari dalam buku
Hasil 1-3 dari 39
Halaman 111
... insulation and the application of new insulation conform to a special gage which is part of the cable splicers ' equipment . The lead sheath is stripped off in the usual way preparatory to jointing . After the conduc- tors are soldered ...
... insulation and the application of new insulation conform to a special gage which is part of the cable splicers ' equipment . The lead sheath is stripped off in the usual way preparatory to jointing . After the conduc- tors are soldered ...
Halaman 114
... insulation at its thickest point is about one and one- quarter times that of the mill applied insulation . A finished con- ductor is shown in Fig 14 which illustrates the smoothly sloping lines obtained by the method of taping . After ...
... insulation at its thickest point is about one and one- quarter times that of the mill applied insulation . A finished con- ductor is shown in Fig 14 which illustrates the smoothly sloping lines obtained by the method of taping . After ...
Halaman 126
... INSULATION Some companies include in their high - tension paper - insulated cable specifications a clause to limit the percentage of moisture in the insulating compound . This appears to be a step in the right direction , but such ...
... INSULATION Some companies include in their high - tension paper - insulated cable specifications a clause to limit the percentage of moisture in the insulating compound . This appears to be a step in the right direction , but such ...
Isi
INTRODUCTION | 7 |
TWO WATTMETER METHOD FOR TESTING CURRENT TRANS | 13 |
TWO WATTHOUR METER METHOD OF TESTING INSTRUMENT | 26 |
37 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
Accident Prevention alternating current ammeter amperes apparatus belt boiler Bureau of Standards cable capacity cent Central Committee central power central station Chairman Chicago circuit City clinker coal coil compound condenser conductors connected considerable construction cost current transformers deg fahr Diesel engine distribution duct efficiency Employees energy equipment finger furnace fuse glove hydro-electric inches increase installed instrument transformers insulation interest joint lamps lightning arresters load manhole manufacturers member companies ment method Niagara Falls obtained operation Organization Overhead Line phase angle plants poles potentiometer Power Company power house practice present pressure primary pump railroad railway ratio recommendations rheostat River rubber secondary Secretary steam stoker street substation supply temperature terminals TESCO tion trans transmission trouble tubes turbine United utilized voltage voltmeter volts water power water-power watthour meters wattmeter wire