Convention, Volume 5;Volume 39;Volume 62 |
Dari dalam buku
Hasil 1-3 dari 26
Halaman 265
... gloves are made in two ways . First , the so - called " built - up " glove is made by hand , vulcanized and steam cured . This type of glove , being cloth lined , is clumsy and lacks flexibility . The other type of glove is made by the ...
... gloves are made in two ways . First , the so - called " built - up " glove is made by hand , vulcanized and steam cured . This type of glove , being cloth lined , is clumsy and lacks flexibility . The other type of glove is made by the ...
Halaman 267
... glove and gauntlet all one piece . All rubber gloves are more flexible than the cloth lined ones . No flaws noticeable . Glove No. 4- Black , cloth lining , with rubberized cloth outside of a layer of rubber , re - enforcements on back ...
... glove and gauntlet all one piece . All rubber gloves are more flexible than the cloth lined ones . No flaws noticeable . Glove No. 4- Black , cloth lining , with rubberized cloth outside of a layer of rubber , re - enforcements on back ...
Halaman 283
... glove should be tested . It is equally important to make periodic tests of all gloves , so that the unsafe ones can ... glove appears to be more generally used on account of its greater flexibility . This type of glove stood up better in ...
... glove should be tested . It is equally important to make periodic tests of all gloves , so that the unsafe ones can ... glove appears to be more generally used on account of its greater flexibility . This type of glove stood up better in ...
Isi
INTRODUCTION | 7 |
TWO WATTMETER METHOD FOR TESTING CURRENT TRANS | 13 |
TWO WATTHOUR METER METHOD OF TESTING INSTRUMENT | 26 |
37 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
Accident Prevention alternating current ammeter amperes apparatus belt boiler Bureau of Standards cable capacity cent Central Committee central power central station Chairman Chicago circuit City clinker coal coil compound condenser conductors connected considerable construction cost current transformers deg fahr Diesel engine distribution duct efficiency Employees energy equipment finger furnace fuse glove hydro-electric inches increase installed instrument transformers insulation interest joint lamps lightning arresters load manhole manufacturers member companies ment method Niagara Falls obtained operation Organization Overhead Line phase angle plants poles potentiometer Power Company power house practice present pressure primary pump railroad railway ratio recommendations rheostat River rubber secondary Secretary steam stoker street substation supply temperature terminals TESCO tion trans transmission trouble tubes turbine United utilized voltage voltmeter volts water power water-power watthour meters wattmeter wire