... considered , the importance of increasing the carrying capacity of cables to the maximum possible value is realized . The problem of determining the proper loading for under- ground cables remains unsolved , but more and more attention ...
... considered , the importance of increasing the carrying capacity of cables to the maximum possible value is realized . The problem of determining the proper loading for under- ground cables remains unsolved , but more and more attention ...
Halaman 492
National Electric Light Association. Convention. ages considered standard above these are 6600 , 11 000 , 13 200 , 16 500 , 22 000 , 33 000 , 44 000 , 66 000 , 88 000 and 110 000 volts . ( 2 ) Since taps are not considered necessary or ...
National Electric Light Association. Convention. ages considered standard above these are 6600 , 11 000 , 13 200 , 16 500 , 22 000 , 33 000 , 44 000 , 66 000 , 88 000 and 110 000 volts . ( 2 ) Since taps are not considered necessary or ...
Halaman 626
... considered . I would like to inquire what is the improvement in efficiency or water rate with steam pressures at 300 , 400 , and 500 pounds , and total steam tempera- tures at 600 , 700 , and 800 degrees respectively , when compared ...
... considered . I would like to inquire what is the improvement in efficiency or water rate with steam pressures at 300 , 400 , and 500 pounds , and total steam tempera- tures at 600 , 700 , and 800 degrees respectively , when compared ...
Isi
INTRODUCTION | 7 |
TWO WATTMETER METHOD FOR TESTING CURRENT TRANS | 13 |
TWO WATTHOUR METER METHOD OF TESTING INSTRUMENT | 26 |
37 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
Accident Prevention alternating current ammeter amperes apparatus belt boiler Bureau of Standards cable capacity cent Central Committee central power central station Chairman Chicago circuit City clinker coal coil compound condenser conductors connected considerable construction cost current transformers deg fahr Diesel engine distribution duct efficiency Employees energy equipment finger furnace fuse glove hydro-electric inches increase installed instrument transformers insulation interest joint lamps lightning arresters load manhole manufacturers member companies ment method Niagara Falls obtained operation Organization Overhead Line phase angle plants poles potentiometer Power Company power house practice present pressure primary pump railroad railway ratio recommendations rheostat River rubber secondary Secretary steam stoker street substation supply temperature terminals TESCO tion trans transmission trouble tubes turbine United utilized voltage voltmeter volts water power water-power watthour meters wattmeter wire