National Building CodeAmerican Insurance Association, Engineering and Safety Service., 1907 |
Edisi yang lain - Lihat semua
Istilah dan frasa umum
anchored apartment house arches ashlar auditorium balconies bolts brick walls brickwork building hereafter erected building or structure built cast iron ceiling cement mortar chimneys Code Commissioner of Buildings connected constructed cornice court covered Department of Buildings diameter doors eight inches elevators exceed exceeding extend feet in height fire limits fire-escape fireproof buildings fireproof material flanges floor beams flues four inches four stories Frame Buildings furnaces gallery girders inches in thickness inches thick inclosed inclosure iron or steel lath and plaster least less than four less than twelve lintels lis pendens load metal non-fireproof notice openings owner party walls person piers pipe placed plates proscenium protected reinforced concrete rivets roof beams safe SECTION shaft side six inches skylights smoke pipe space square inch stairs standpipe stone stories in height strength stresses supported tenement house thereof three feet twelve inches width window woodwork wrought iron
Bagian yang populer
Halaman 20 - tenement-house '' shall be taken to mean and include every house, building, or portion thereof, which is rented, leased, let or hired out to be occupied, or is occupied, as the home, or residence of three families or more, living independently of each other, and doing their cooking upon the premises, or by more than two families upon any floor, so living and cooking, but having a common right in the halls, stairways, yards, water-closets, or privies, or some of them.
Halaman 202 - Distinct and separate places of exit and entrance shall be provided for each gallery above the first. A common place of exit and entrance may serve for the main floor of the auditorium and the first gallery, provided Its capacity be equal to the aggregate capacity of the outlets from the main floor and the said gallery. No passage leading to any stairway communicating with any entrance or exit shall be less than four feet in width in any part thereof.
Halaman 110 - If elevators, elevating machines or hod-hoisting apparatus are used within a building in the course of construction, for the purpose of lifting materials to be used in such construction, the contractors or owners shall cause the shafts or openings in each floor to be inclosed or fenced in on all sides by a barrier at least eight feet in height...
Halaman 61 - Recesses for stairways or elevators may be left in the foundation or cellar walls of all buildings, but in no case shall the walls be of less thickness than the walls of the fourth story, unless reinforced by additional piers with iron or steel girders, or iron or steel columns and girders, properly insulated, and securely anchored to walls on each side.
Halaman 69 - The depth of the yard behind every tenement house hereafter erected upon a corner lot shall be not less than ten feet in every part...
Halaman 220 - ... of the foundation thereof, at the time of such damage, may be repaired or rebuilt; but if such damage shall amount to more than one-half of such value thereof, exclusive of the value of the foundation, then such building shall not be repaired or rebuilt, but shall be taken down, except as provided in this Code.
Halaman 193 - ... the theatre, on each tier, equal to the combined width of exits opening on opposite sides in each tier, communicating with balconies and staircases leading to the street in...
Halaman 79 - Such room shall have a window or windows opening upon the street, or upon a yard or court. The total area of windows in such room shall be at least one-eighth of the superficial area of the room, and one-half of the sash shall be made to open the full width, and the top of each window shall be within six inches of the ceiling.
Halaman 235 - Code, is being erected, constructed, altered or repaired, or has been erected, constructed, altered or repaired, in violation of, or not in compliance with, any of the provisions...
Halaman 61 - Recesses for alcoves and similar purposes shall have not less than eight inches of brickwork at the back of such recesses, and such recesses shall be not more than eight feet in width, and shall be arched over or spanned with iron or steel lintels, and not carried up higher than eighteen inches below the bottom of the beams of the floor next above. CHASES FOR PIPES. No chase for water or other pipes shall be made in any pier, and in no wall more than one-third of its thickness. The chases around...