The terminals shall be so marked that when connection is made to a secondary terminal bearing the same marking as a given primary terminal , the polarity will be the same as if the primary service conductor itself were detached from the ...
The terminals shall be so marked that when connection is made to a secondary terminal bearing the same marking as a given primary terminal , the polarity will be the same as if the primary service conductor itself were detached from the ...
Halaman 12
With a potential transformer , the volt - ampere load is practically dependent only upon the secondary amperes , since the voltage is nearly constant . With a current transformer , however , the volt - ampere load depends upon both ...
With a potential transformer , the volt - ampere load is practically dependent only upon the secondary amperes , since the voltage is nearly constant . With a current transformer , however , the volt - ampere load depends upon both ...
Halaman 25
ers , with the given secondary loads . For example , suppose that the wattmeter constants are those previously referred to , and the 150 - volt potential circuit is in use , so that one division deflection is given by 1 volt applied to ...
ers , with the given secondary loads . For example , suppose that the wattmeter constants are those previously referred to , and the 150 - volt potential circuit is in use , so that one division deflection is given by 1 volt applied to ...
Apa yang dikatakan orang - Tulis resensi
Kami tak menemukan resensi di tempat biasanya.
Isi
TWO VOLTMETER METHOD FOR TESTING POTENTIAL TRANS | 16 |
TWO WATTHOUR METER METHOD OF TESTING INSTRUMENT | 26 |
RECENT DEVELOPMENTS | 36 |
19 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
Accident Prevention accidents amount apparatus arresters Association belt bill boiler Bureau cable capacity carried cause cent central circuit City coal Committee companies complete connected considerable considered construction cost desirable determined discussion distribution effect efficiency electric Employees energy engine equipment Falls finger give given glove hand important inches increase indicate installed insulation interest joint lamps lead less light load manufacturers material matter means measured meetings meter method necessary obtained operation Organization phase placed plants poles possible practice present pressure production protection railroad ratio reason recommendations River rules safety secondary Secretary side standard station steam street supply taken temperature terminal tion transformers transmission trouble tubes turbine United utilized various voltage volts water power York