Halaman 48
Usually there is not much difficulty in placing the main horizontal busbars at a safe distance from the meters . Vertical busbars , as a rule , must be closer to the panel , and often can not be placed more than a few inches from it ...
Usually there is not much difficulty in placing the main horizontal busbars at a safe distance from the meters . Vertical busbars , as a rule , must be closer to the panel , and often can not be placed more than a few inches from it ...
Halaman 98
The main service box , placed in the outside wall of the building , is accessible at all times to the Company's employees for refusing , inspection , etc. , and also to firemen or other municipal agents who might desire to discontinue ...
The main service box , placed in the outside wall of the building , is accessible at all times to the Company's employees for refusing , inspection , etc. , and also to firemen or other municipal agents who might desire to discontinue ...
Halaman 119
The insulating material is placed in the can in layers in the order required to make up the joint , so that all of the material in each layer has to be used in its entirety in each successive operation . The illustration shows all the ...
The insulating material is placed in the can in layers in the order required to make up the joint , so that all of the material in each layer has to be used in its entirety in each successive operation . The illustration shows all the ...
Apa yang dikatakan orang - Tulis resensi
Kami tak menemukan resensi di tempat biasanya.
Isi
TWO VOLTMETER METHOD FOR TESTING POTENTIAL TRANS | 16 |
TWO WATTHOUR METER METHOD OF TESTING INSTRUMENT | 26 |
RECENT DEVELOPMENTS | 36 |
19 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
Accident Prevention accidents amount apparatus arresters Association belt bill boiler Bureau cable capacity carried cause cent central circuit City coal Committee companies complete connected considerable considered construction cost desirable determined discussion distribution effect efficiency electric Employees energy engine equipment Falls finger give given glove hand important inches increase indicate installed insulation interest joint lamps lead less light load manufacturers material matter means measured meetings meter method necessary obtained operation Organization phase placed plants poles possible practice present pressure production protection railroad ratio reason recommendations River rules safety secondary Secretary side standard station steam street supply taken temperature terminal tion transformers transmission trouble tubes turbine United utilized various voltage volts water power York