My electrolyser has all the advantages of the urethrotome and none of its inconveniences. It looks like a small whip of which the handle contains a metallic wire projecting from the end which connects with the flexible part. This instrument, being first... The Medical News - Halaman 1901896Tampilan utuh - Tentang buku ini
| 1896 - 606 halaman
...which connects with the flexible part. This instrument, being first introduced into the urethra, is connected with the negative pole of a continuous current battery, and the postive pole is connected near the affected part, on the front of the thigh or over the pube.s then... | |
| 1896 - 506 halaman
...which connects with the flexible part. This instrument, being first introduced into the urethra, is connected with the negative pole of a continuous current battery, and the positive pole is connected near the affected part, on the front of thigh or over the pubes; then the current is turned... | |
| 1896 - 886 halaman
...face of the stricture. The instrument is then connected with the negative pole of a continuous-current battery, and the positive pole, which is flat and...turned on. This should be, in general, of a strength of ю milliampères, as shown by an attached galvanometer. During the operation the electrolytic blade... | |
| Charles Marchand - 1896 - 240 halaman
...which connects with the flexible part. This instrument, being first introduced into the urethra, is connected with the negative pole of a continuous current battery, and the positive pole is connected near the affected part, on the front of the thigh or over the pubes; then the current... | |
| 1896 - 528 halaman
...which connects with the flexible part. This instrument, being first introduced into the urethra, is connected with the negative pole of a continuous current battery, and the positive pole ia connected near the affected part, on the front of the thigh or over the pubes; then the current... | |
| 1896 - 422 halaman
...which connects with the flexible part. This instrument, being first intro duced into the urethra, is connected with the negative pole of a continuous current battery, and the positive pole is connected near the affected part, on the front of the thigh or over the pubes ; then the current... | |
| 1896 - 562 halaman
...which connects with the flexible part. This instrument, being first introduced into the urethra, is connected with the negative pole of a continuous current battery, and the positive pole is connected near the affected part, on the front of the thigh or over the pubes; then the current... | |
| 1896 - 1088 halaman
...which connects with the flexible part. This instrument, being first introduced into the urethra,is connected with the negative pole of a continuous current battery, and the positive pole is connected near the affected part, on the front of the thigh or over the pubes; then the current... | |
| 1896 - 610 halaman
...which connects with the flexible part. This instrument, being first introduced into the urethra, is connected with the negative pole of a continuous current battery, and the postive pole is connected near the affected part, on the front of the thigh or over the pubes; then... | |
| Robert William Taylor - 1900 - 814 halaman
...portion, is bent so aa to form an obtuse conical projection, which resembles the blade of Maisonncuve's instrument. This platinum blade, therefore, is the...on. This should be, in general, of a strength of ten milliampcres, as shown by an attached galvanometer. During the operation, the electrolytic blade remains... | |
| |