" Where smoke pipes pass through a lath and plaster partition they shall be guarded by galvanized iron ventilated thimbles at least twelve inches larger in diameter than the pipes, or by galvanized iron thimbles built in at least eight inches of brickwork. "
Gas, Gasoline and Oil Engines - Halaman 185
oleh Archie Frederick Collins - 1919 - 206 halaman
Tampilan utuh - Tentang buku ini

The Building Code of the City of New York

New York (N.Y.) - 1901 - 186 halaman
...and plaster partition they shall be guarded by galvanized iron ventilated thimbles at least twelve inches larger in diameter than the pipes, or by galvanized iron thimbles built in at least eight inches of brickwork. No smoke pipe shall pass through the roof of any building unless a special...
Tampilan utuh - Tentang buku ini

Building-law of the Town of Brookline, Adopted March 31, 1903, Approved by ...

Brookline (Mass.). - 1903 - 142 halaman
...and plaster partition they shall be guarded by galvanized iron ventilated thimbles at least twelve inches larger in diameter than the pipes, or by galvanized iron thimbles built in at least eight inches of brickwork. No smoke pipe shall pass through the roof of any building unless a special...
Tampilan utuh - Tentang buku ini

National Building Code

1905 - 274 halaman
...plaster through partition they shall be guarded by galvanized iron ventilated thimbles at least twelve inches larger in diameter than the pipes, or by galvanized iron thimbles built in at least eight inches of brickwork. Smoke Pipes Through Roofs. Permit No smoke pipe shall pass through the roof...
Tampilan utuh - Tentang buku ini

Code of Ordinances of the City of New York

New York (N.Y.) - 1907 - 462 halaman
...and plaster partition they shall be guarded by galvanized iron ventilated thimbles at least twelve inches larger in diameter than the pipes, or by galvanized iron thimbles built in at least eight inches of brickwork. No smoke pipe shall pass through the roof of any building unless a special...
Tampilan utuh - Tentang buku ini

Code of Ordinances of the City of New York: Approved November 8, 1906 ...

New York (N.Y.) - 1908 - 466 halaman
...and plaster partition they shall be guarded by galvanized iron ventilated thimbles at least twelve inches larger in diameter than the pipes, or by galvanized iron thimbles built in at least eight inches of brickwork. No smoke pipe shall pass through the roof of any building unless a special...
Tampilan utuh - Tentang buku ini

The Building Code of the City of Jersey City, 1907

Jersey City (N.J.). - 1908 - 298 halaman
...partition they shall be guarded by gal- *oo"* f*'vanized iron ventilated thimbles at least twelve l IBns' inches larger in diameter than the pipes, or by galvanized iron thimbles built in at least eight inches of brickwork. Smoke Pipes Through Roofs. No smoke pipe shall pass through the roof of...
Tampilan utuh - Tentang buku ini

Building Code of the City of Richmond

Richmond (Va.). - 1908 - 132 halaman
...and plaster partition they shall be guarded by galvanized iron ventilated thimbles at least eight (8) inches larger in diameter than the pipes, or by galvanized iron thimbles built in at least nine (9) inches of brickwork. SMOKE PIPES THROUGH ROOFS. b. No smoke pipe shall pass through the roof...
Tampilan utuh - Tentang buku ini

Building Code Recommended by the National Board of Fire Underwriters ...

National Board of Fire Underwriters - 1909 - 280 halaman
...and plaster partition they shall be guarded by galvanized iron ventilated thimbles at least twelve inches larger in diameter than the pipes, or by galvanized iron thimbles built in at least eight inches of brickwork. Smoke Pipes Through Roofs, Permit No smoke pipe shall pass through the roof...
Tampilan utuh - Tentang buku ini

National Building Code Recommended by the National Board of Fire ...

National Board of Fire Underwriters - 1909 - 276 halaman
...and plaster partition they shall be guarded by galvanized iron ventilated thimbles at least twelve inches larger in diameter than the pipes, or by galvanized iron thimbles built in at least eight inches of brickwork. Smoke Pipes Through Roofs. Permit necessary. No smoke pipe shall pass through...
Tampilan utuh - Tentang buku ini

Revised Ordinances: Revision of 1906, in Effect January 1st, 1907, with ...

Fitchburg (Mass.). - 1912 - 296 halaman
...they shall be guarded by galvanized iron ventilated thimblesat least twelve inches larger indiameter than the pipes or by galvanized iron thimbles built in at least eight inches of brick work. (i) Ducts for Ventilation. — Vent flues or ducts for the removal of foul...