Halaman 977
... Transformer Accessories The Committee recommends for adoption as standard the following accessories : For all single phase and three phase distribution transformers : See Table CXV . For all single and three phase power transformers ...
... Transformer Accessories The Committee recommends for adoption as standard the following accessories : For all single phase and three phase distribution transformers : See Table CXV . For all single and three phase power transformers ...
Halaman 984
... transformer manufacturers are not uniform on angular displace- ment for delta - delta and Y - Y transformers and it has been suggested that uniformity among manu- facturers on this point would be desirable from an operating standpoint ...
... transformer manufacturers are not uniform on angular displace- ment for delta - delta and Y - Y transformers and it has been suggested that uniformity among manu- facturers on this point would be desirable from an operating standpoint ...
Halaman 989
... transformers are briefly described in the 1921 report of the Transformer Sub- committee . Fig . 640 shows the core and coils of one of these transformers , and Fig . 641 is a view of the station showing a bank of the 220,000 - volt ...
... transformers are briefly described in the 1921 report of the Transformer Sub- committee . Fig . 640 shows the core and coils of one of these transformers , and Fig . 641 is a view of the station showing a bank of the 220,000 - volt ...
Isi
Report of Prime Movers Committee Continued | 699 |
30 P M | 920 |
45 P M | 1044 |
6 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current apparatus boiler burners burning capacity carbon cent central station Chairman circuit breaker coil combustion condenser connected corrosion damper device direct current duty cycle Edison Company efficiency Electric Company Electric Light Association engineers equipment Executive Committee Fahr feed water fire fuel oil furnace Gas and Electric heat heater indicated inductive installed insulator kv-a Light and Power Light Company lignite load manufacturers member companies method motor National Electric Light National Section oil pressure Oil Shale operation oxygen pany phase pipe plant poles Power Company power factor practice pump relay rheostat Shale short circuit shown in Fig Southern California Edison specifications standard steam pressure steel Subcommittee substation superheat supply surface switch tank telephone Telf temperature tion transformers tubes turbine units utilities valve volt ampere voltage volts Western Red Cedar wire York zeolite