... supply the demand of domestic consumption alone , without any petroleum for export being con- sidered . It does not seem likely that there will be any greatly enlarged production in the future from sources within the United States ...
... supply the demand of domestic consumption alone , without any petroleum for export being con- sidered . It does not seem likely that there will be any greatly enlarged production in the future from sources within the United States ...
Halaman 828
... supply ; another 25,000 bar- rels or twenty days ' supply ; another 35,000 bar- rels , or enough for from seven to ten days ; an Atlantic Seaboard Company has tankage of 6000 barrels , equivalent to about twenty days ' supply ; another ...
... supply ; another 25,000 bar- rels or twenty days ' supply ; another 35,000 bar- rels , or enough for from seven to ten days ; an Atlantic Seaboard Company has tankage of 6000 barrels , equivalent to about twenty days ' supply ; another ...
Halaman 969
... supply and distribu- tion described . Particular attention was called to the use of 2300 - volt motors in sizes of 100 hp . and above . It is interesting to note that almost all of the aux- iliaries in the new Hell Gate Station in New ...
... supply and distribu- tion described . Particular attention was called to the use of 2300 - volt motors in sizes of 100 hp . and above . It is interesting to note that almost all of the aux- iliaries in the new Hell Gate Station in New ...
Isi
Report of Prime Movers Committee Continued | 699 |
30 P M | 920 |
45 P M | 1044 |
6 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current apparatus boiler burners burning capacity carbon cent central station Chairman circuit breaker coil combustion condenser connected corrosion damper device direct current duty cycle Edison Company efficiency Electric Company Electric Light Association engineers equipment Executive Committee Fahr feed water fire fuel oil furnace Gas and Electric heat heater indicated inductive installed insulator kv-a Light and Power Light Company lignite load manufacturers member companies method motor National Electric Light National Section oil pressure Oil Shale operation oxygen pany phase pipe plant poles Power Company power factor practice pump relay rheostat Shale short circuit shown in Fig Southern California Edison specifications standard steam pressure steel Subcommittee substation superheat supply surface switch tank telephone Telf temperature tion transformers tubes turbine units utilities valve volt ampere voltage volts Western Red Cedar wire York zeolite