Halaman 979
... Standard Frequencies : 25 and 60 cycles per second . Standard Sizes and Voltage Ratings : 6600Y to 2300 delta in sizes 10 11,000Y to 2300 delta in sizes 10 13,200Y to 2300 delta in sizes 10 22,000Y to 2300 delta in sizes 15 33,000Y to ...
... Standard Frequencies : 25 and 60 cycles per second . Standard Sizes and Voltage Ratings : 6600Y to 2300 delta in sizes 10 11,000Y to 2300 delta in sizes 10 13,200Y to 2300 delta in sizes 10 22,000Y to 2300 delta in sizes 15 33,000Y to ...
Halaman 980
... STANDARD TYZES , FERQUNICIES , SIZES AND VOLTAGE RATINGS STANDARD 81238 IB KVA CONTINUOUS MATINGS AT 5600 . 011 Immersed 011 Irood Self Cooled Uil immersed Later Cooled Water Cooled 013 Immersed Self Cooled or Air Meat Air Blast 3028 ...
... STANDARD TYZES , FERQUNICIES , SIZES AND VOLTAGE RATINGS STANDARD 81238 IB KVA CONTINUOUS MATINGS AT 5600 . 011 Immersed 011 Irood Self Cooled Uil immersed Later Cooled Water Cooled 013 Immersed Self Cooled or Air Meat Air Blast 3028 ...
Halaman 982
... STANDARD TRANSFORMER VOLTAGES AND PRE- FERRED STANDARD TRANSFORMER KV - A . SIZES The preferred transformer voltages and transformer kva . sizes are those designated by " * " . Standard Sizes in Kv - a . Continuous Ratings at 55 ° C ...
... STANDARD TRANSFORMER VOLTAGES AND PRE- FERRED STANDARD TRANSFORMER KV - A . SIZES The preferred transformer voltages and transformer kva . sizes are those designated by " * " . Standard Sizes in Kv - a . Continuous Ratings at 55 ° C ...
Isi
Report of Prime Movers Committee Continued | 699 |
30 P M | 920 |
45 P M | 1044 |
6 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current apparatus boiler burners burning capacity carbon cent central station Chairman circuit breaker coil combustion condenser connected corrosion damper device direct current duty cycle Edison Company efficiency Electric Company Electric Light Association engineers equipment Executive Committee Fahr feed water fire fuel oil furnace Gas and Electric heat heater indicated inductive installed insulator kv-a Light and Power Light Company lignite load manufacturers member companies method motor National Electric Light National Section oil pressure Oil Shale operation oxygen pany phase pipe plant poles Power Company power factor practice pump relay rheostat Shale short circuit shown in Fig Southern California Edison specifications standard steam pressure steel Subcommittee substation superheat supply surface switch tank telephone Telf temperature tion transformers tubes turbine units utilities valve volt ampere voltage volts Western Red Cedar wire York zeolite