... given period . This is equal to the aggregate total heat of steam leaving the boiler minus the total heat of an equal weight of water entering the economizer . 9. Gross Boiler Room Output Sum of gross outputs of individual boilers or ...
... given period . This is equal to the aggregate total heat of steam leaving the boiler minus the total heat of an equal weight of water entering the economizer . 9. Gross Boiler Room Output Sum of gross outputs of individual boilers or ...
Halaman 912
... given period , divided by the product of the total num- ber of generators in the system times the number of hours in that period . 10. Generating Unit Availability Factor The ratio of the sum of the total number of hours that a ...
... given period , divided by the product of the total num- ber of generators in the system times the number of hours in that period . 10. Generating Unit Availability Factor The ratio of the sum of the total number of hours that a ...
Halaman 913
... given period divided by the gross generating system output in kw- hr . in the same period . D. EFFICIENCY BASIS ( 1 ) Gross generating system efficiency . The ratio of the gross generating system output in kw - hr . during a given ...
... given period divided by the gross generating system output in kw- hr . in the same period . D. EFFICIENCY BASIS ( 1 ) Gross generating system efficiency . The ratio of the gross generating system output in kw - hr . during a given ...
Isi
Report of Prime Movers Committee Continued | 699 |
30 P M | 920 |
45 P M | 1044 |
6 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
alternating current apparatus boiler burners burning capacity carbon cent central station Chairman circuit breaker coil combustion condenser connected corrosion damper device direct current duty cycle Edison Company efficiency Electric Company Electric Light Association engineers equipment Executive Committee Fahr feed water fire fuel oil furnace Gas and Electric heat heater indicated inductive installed insulator kv-a Light and Power Light Company lignite load manufacturers member companies method motor National Electric Light National Section oil pressure Oil Shale operation oxygen pany phase pipe plant poles Power Company power factor practice pump relay rheostat Shale short circuit shown in Fig Southern California Edison specifications standard steam pressure steel Subcommittee substation superheat supply surface switch tank telephone Telf temperature tion transformers tubes turbine units utilities valve volt ampere voltage volts Western Red Cedar wire York zeolite