Dari dalam buku
Hasil 1-3 dari 47
Halaman 1176
Boiler Equipped with Babcock & Wilcox Lodi Type Burner with Individual Oil Meter . with mechanical burners , although from 100 to 5. Regulation of Fuel Supply 175 per cent of rating may be secured with natural Oil fuel may be burned ...
Boiler Equipped with Babcock & Wilcox Lodi Type Burner with Individual Oil Meter . with mechanical burners , although from 100 to 5. Regulation of Fuel Supply 175 per cent of rating may be secured with natural Oil fuel may be burned ...
Halaman 1184
Mechanical burners will almost from every mechanical burner in the plant , a very invariably require more draft to ... may be taken care of in a of difference depending upon the number of burners number of ways with mechanical burners .
Mechanical burners will almost from every mechanical burner in the plant , a very invariably require more draft to ... may be taken care of in a of difference depending upon the number of burners number of ways with mechanical burners .
Halaman 1199
The records in oil burning were made , although the oil amount of oil burned per burner per hour during per burner per ... the efficiency of the burners had Navy and Merchant Marine , none of them being greatly increased , no difficulty ...
The records in oil burning were made , although the oil amount of oil burned per burner per hour during per burner per ... the efficiency of the burners had Navy and Merchant Marine , none of them being greatly increased , no difficulty ...
Apa yang dikatakan orang - Tulis resensi
Kami tak menemukan resensi di tempat biasanya.
Isi
25 P M | 649 |
Report of Inductive Interference Committee A E Silver Chairman | 856 |
30 P M | 879 |
6 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
amount arms arrangement average boiler burners capacity carried cause cent circuit close coal Committee Company conductor connection considerable construction cost covering desired draft economizer effect efficiency Electric Engineering equipment experience feed feet fire fuel furnace give given ground wires heat higher hour important inch increased indicate installed insulators interest iron less Light lignite limit load loss lower manufacturers material means mechanical method necessary obtained operation pins pipe plant poles possible practice present pressure problem production pulverized pump reduced removed shown shows specifications standard station steam steel stoker superheat supply surface TABLE tank temperature tion treated treatment trouble tubes turbine units usually valve voltage wood