The arrangement used in suspension construction ductor and the arm where the string is pulled out of is much more uniform than in pin type construction . line by the change in direction of the line . For single pole work the usual ...
The arrangement used in suspension construction ductor and the arm where the string is pulled out of is much more uniform than in pin type construction . line by the change in direction of the line . For single pole work the usual ...
Halaman 691
Where two circuits are installed the conductors are arranged vertically , three “ All transmission line ... alone we believe specify the lengths to be shipped in each coil or on the best arrangement of conductors is at the points each ...
Where two circuits are installed the conductors are arranged vertically , three “ All transmission line ... alone we believe specify the lengths to be shipped in each coil or on the best arrangement of conductors is at the points each ...
Halaman 1048
In the unit system of piping layout where say , four or six boilers are arranged to feed one turbine through the header , tie lines are usually provided ... 2 arrangement provides for completely isolating a set of boilers and turbines .
In the unit system of piping layout where say , four or six boilers are arranged to feed one turbine through the header , tie lines are usually provided ... 2 arrangement provides for completely isolating a set of boilers and turbines .
Apa yang dikatakan orang - Tulis resensi
Kami tak menemukan resensi di tempat biasanya.
Isi
25 P M | 649 |
Report of Inductive Interference Committee A E Silver Chairman | 856 |
30 P M | 879 |
6 bagian lainnya tidak diperlihatkan
Edisi yang lain - Lihat semua
Istilah dan frasa umum
amount arms arrangement average boiler burners capacity carried cause cent circuit close coal Committee Company conductor connection considerable construction cost covering desired draft economizer effect efficiency Electric Engineering equipment experience feed feet fire fuel furnace give given ground wires heat higher hour important inch increased indicate installed insulators interest iron less Light lignite limit load loss lower manufacturers material means mechanical method necessary obtained operation pins pipe plant poles possible practice present pressure problem production pulverized pump reduced removed shown shows specifications standard station steam steel stoker superheat supply surface TABLE tank temperature tion treated treatment trouble tubes turbine units usually valve voltage wood